Page 6 of 12 AquaRite Flo Advanced Rev. B
5. ELECTROLYSIS
6. MEASUREMENTS / Setpoints
6.1. MEASUREMENTS – pH calibration
5.1 5.2 5.3 5.4
5.1 Electrolysis:
Programming of electrolysis
functions.
5.2 Level:
Desired chlorine production (g/h).
5.3 Boost (superchlorination):
Filtration for 24h at maximum
intensity. Automatic return to
programmed ltration mode.
During the boost period the Rx
control can be deactivated.
5.4 Cover:
Reduction of chlorine production
activated by closing the automatic
cover.
See section on Cover.
6.1 6.2 6.3
6.1 Measurements:
Adjustment of setpoints and
measuring probes.
6.3 Setpoint settings:
conguration of the ideal levels for
each parameter.
6.2 Setpoints for each
measurement.
Default values:
pH: 7.2 – 7.5
Rx: 600 – 800
Connection 6.4 6.5 6.6
6.4 Calibration of pH probe:
Recommended every month during
the season of use.
6.6 Example of rst step of
calibration with bu󰀨ers.
Continue with the following steps.
6.5 Calibration with bu󰀨ers (bu󰀨er
solutions pH7 / pH10 / neutral):
Follow the 7-step instructions that
are shown on the display.
6.7 6.8
6.8 Without removing the probe
from the water, use the plus / minus
keys to adjust the reading so it
matches with your reference value
(photometer or other measuring
device).
6.7 Manual calibration: Allows
adjustment of the probes to
1 objective measurement (without
bu󰀨ers) – only recommended for
correction of small deviations in the
readings.
Measurement and control of
the pH of the water
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hayward Aqua Rite Flo Advanced at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hayward Aqua Rite Flo Advanced in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Norwegian as an attachment in your email.

The manual is 94.1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info