4.1. Weather conditions
For the safe operation of the fireplace, it must be ensured that the chimney is able to build up the necessary flue draft.
Particular attention needs to be paid to this during the transition period (e.g. autumn and spring) or during poor
weather conditions (e.g. strong wind, fog etc.).
4.2. Chimney flue draft at rated heat output of the stove
min. flue draft
6 Pa
if the minimum flue draft is not reached, then it is not possible to
operate the fireplace properly and it will lead to increased
contamination of the burner and inspection window.
max. flue draft
15 Pa
if the maximum permitted flue draft is exceeded, this leads to
increased fuel consumption.
4.3. Connection to the chimney
For the connection to the chimney, gas-tight flue tubes should be used. Approved flex steel tubes
are also suitable. Please observe the national regulations.
The flue tube must be securely fitted on the flue gas spigot.
The flue gas tube must not be installed with a drop to the chimney.
It is also essential to ensure that the flue tube does not stick out into the open cross-section of the
chimney, which would interfere with the flue gases rising and prevent the optimal cleaning of the
chimney.
The use of wall lagging is recommended for the insertion into the chimney (see Figure 3).
Longer horizontal flue gas connections reduce the necessary flue draft.
All openings leading into the same chimney, such as stove and chimney cleaning apertures, must
be closed.
4.3.1. Multiple use
The stove is not approved for multiple use.
5. Installation
5.1. Minimum gaps to flammable components:
When installing the stove, it is essential to observe the official fire protection regulations.
Please observe the national regulations to this effect.
As the minimum distances from flammable or temperature-sensitive materials (e.g. furniture, wallpaper,
wooden cladding) and from load-bearing walls, the specified gaps “at the back”, “on the sides” and in the “direction of
radiation forwards” must be maintained according to the nameplate.
Floor protection:
In case of flammable or temperature-sensitive floor coverings, the
appliance must be placed on a non-flammable base (see drawing).
Recommendation for floor protection:
A 30 cm at the front
B 10 cm at the sides
C up to the back wall
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Haas-Sohn PELLETTO-RLU 418.08 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Haas-Sohn PELLETTO-RLU 418.08 in the language / languages: English as an attachment in your email.

The manual is 0.59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Haas-Sohn PELLETTO-RLU 418.08

Haas-Sohn PELLETTO-RLU 418.08 Usermanual and installation guide - German - 34 pages

Haas-Sohn PELLETTO-RLU 418.08 User Manual - French - 22 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info