16. Sensor flame temperature interruption (23)
Cause: Flame temperature sensor defective or not
connected
Remedy:
Contact service technician
17. Sensor flame temperature short circuit (24)
Cause:
Flame temperature sensor defective
Remedy:
Contact service technician
18. Induced draft blower unable to reach set speed
(15)
Cause: The induced draft blower does not run with
the correct speed
This can be caused by the following:
¾ Induced draft blower defective
¾ Connecting line from speed pickup (hall
sensor) is interrupted or there is poor contact
in the connector of this connecting line
¾ Power supply to blower motor interrupted
Remedy:
¾ Contact service technician
19. Convection air blower unable to reach set
speed (16)
Cause: The convection air blower does not run
with the correct speed.
This can be caused by the following:
¾ Convection air blower defective
¾ Connecting line from speed pickup (hall
sensor) is interrupted or there is poor contact
in the connector of this connecting line
¾ Power supply line to blower motor interrupted
Remedy:
¾ Contact service technician
20. No connection to the boiler board – check cable
(17)
Cause: The connection between the central unit
and the operating unit is interrupted.
This can be caused by the following:
Connecting cable is not connected to
the operating unit or the central unit
Connecting cable is damaged
Remedy:
Check if the connecting cable is connected to both
units, operating unit and central unit.
Contact service technician
21. Disconnection following power failure (18)
Cause:
A safety shutdown was initiated through a
power failure
Remedy:
¾ Acknowledge error on the operating unit and
restart the device
22. Disconnection - airflow insufficient during
cleaning (20)
Cause: The airflow measured during the burner test
conducted during heating mode was
insufficient
This can be caused by the following:
Burner is dirty
Airflow sensor is dirty
Intake filter dirty
Vapour extraction hood switched on in the
vicinity
Room too tight - required combustion air is
unable to flow into the room
Leaks on the pellet oven (door, seals)
Backpressure in chimney
Remedy:
¾ Clean burner, intake filter and airflow sensor
¾ Check if a vapour extraction hood is switched
on in the vicinity
¾ Ensure the supply of the required combustion
air, e.g. slightly open the window
¾ Check chimney is not obstructed
¾ Contact service technician
23. Set airflow cannot be reached (19)
Cause:
Insufficient combustion air is supplied to the
oven
This can be caused by the following:
Burner is dirty
Airflow sensor is dirty
Intake filter dirty
Vapour extraction hood switched on in the
vicinity
Room too tight - required combustion air is
unable to flow into the room
Leaks on the pellet oven (door, seals)
¾ Backpressure in chimney
Remedy:
¾ Clean burner, intake filter and airflow sensor
¾ Check if a vapour extraction hood is switched
on in the vicinity
¾ Ensure the supply of the required combustion
air, e.g. slightly open the window
¾ Check chimney is not obstructed
¾ Contact service technician
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Haas-Sohn COMPACT-PELLET 309 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Haas-Sohn COMPACT-PELLET 309 in the language / languages: English as an attachment in your email.

The manual is 3.71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Haas-Sohn COMPACT-PELLET 309

Haas-Sohn COMPACT-PELLET 309 User Manual - German - 43 pages

Haas-Sohn COMPACT-PELLET 309 User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info