regard to fuel-engineering efficiency and
flue-gas emissions are observed.
The pellet-stove may be connected to a
chimney supporting multiple connections,
if the chimney dimensions according to
DIN 4705 Part 2 permit this.Please note
that the minimum feed pressure must
be 6 Pascal and maximum feed
pressure should be maximum 20
Pascal !!
The furnace door may only be opened for
cleaning and maintenance during the
operating state „Off“. Otherwise – even
when the stove is not operated - this is to
be kept closed, in order to avoid an
impairment of other fireplaces and thereby
associated dangers.
A sufficient supply of fresh air to the
installation room must be ensured. The
pellet stove however offers you the
possibility to be connected directly with
outside air via a suitable air duct. With
that, an operation independent of room air
is possible (see chapter 3 „Installation of
the Pellet Stove and Connection to the
Chimney“).
Attention! The pellet stove may not be
set into operation during the joint
operation of domestic aeration- and
ventilation systems.
The chimney (chimney or flue resp.) must
be designed from stainless steel or
ceramic (glazed inside) and be suitable for
low waste gas temperatures, so that this
can not soot up.
The pellet stove may first be connected to
the power network after proper
professional connection to the chimney.
Attention! The mains cable plug must
remain freely accessible after the
installation.
The pellet stove may only be operated
with standardized wood pellets (6 mm
diameter) (see chapter 6.1 „Fuel“).
The protective grating located in the pellet
container must not be removed.
The placing of non-heat-resistant
materials and objects on the stove or
within the prescribed minimum distances
is forbidden. Please take note in particular
thereby, that during the operating state
„Standby“, after cooling down to the
required room temperature, the stove can
begin its heating operation unexpectedly
and unobserved.
Never use liquid fuels to set the pellet
stove into operation or to refresh the
existing embers.
Through the burning of combustible
material, thermal energy is released which
leads to the surfaces of the heating device
heating up greatly (e.g. doors, door- and
operating handles, inspection window
panes, side walls, front wall, flue pipes).
Contact with these parts without suitable
heat-protection gloves or a tool is to be
avoided!
The device starts automatically in
"Standby-Mode". Due to the development
of heat on the panel, it is to be ensured,
that there are no unsupervised persons in
the place of installation who are not
familiarized with the pellet stove.
Make your children and guests aware of
these dangers!
Possibly existing cleaning personnel are
to be especially informed, instructed
respectively with regard to the possible
unexpected heating up of the stove.
The placing of non-heat-resistant objects
on the heating device or close to it (even
when cold, since the stove can start
automatically) is forbidden!
Do not place items of laundry on the stove
to dry!
Stands for drying clothes or the like must
be set up at an adequate distance from
the heating device – danger of fire!
When operating your heating device, the
processing of lightly combustible and
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Haas-Sohn COMPACT-PELLET 309 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Haas-Sohn COMPACT-PELLET 309 in the language / languages: English as an attachment in your email.

The manual is 3.71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Haas-Sohn COMPACT-PELLET 309

Haas-Sohn COMPACT-PELLET 309 User Manual - German - 43 pages

Haas-Sohn COMPACT-PELLET 309 User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info