TIG 220 DC / 300 DC
EN
TROUBLESHOOTING
This device integrates a default management system.
A series of messages displayed on the control board allows for a fault and anomalies diagnosis.
ANOMALIES AND
MMI DISPLAY
CAUSES SOLUTIONS
WELDING MACHINE
« dEF » « 1 » Communication error
Check the internal cabling between the MMI and the
PCB.
« dEF » « 2 » Faulty MMI buttons Replace the MMI.
« dEF » « 3 » Faulty torch(es) trigger(s) / button(s) Replace the torch.
« dEF » « 4 » Foot pedal switch always active or faulty
Replace the pedal and check that the switch is not
stuck.
« E r r » « Co.5 » In automaton mode, a command default is detected. Check the automaton's cabling.
« - - - »
An overvoltage was detected on the electrical distribution
network.
A power surge is the origin of the message and origi-
nates from a motor overload, lightning…
« P h » 1 phase missing from the three phase network. The installation must be three phase (3P+N+E)
« d E »
A voltage unbalance was detected on the electrical distribution
network.
Call your supplier.
WELDING MACHINE + COOLING UNIT
« Pb.1 » Cooling unit detection default.
Check the connectors between the welding current
source.
« Pb.2 » Cooling liquid supply default. Fill the cooling unit's tank.
« Pb.3 » Cooling liquid ow default.
Check the liquid ow's between the unit and the
torch.
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gys TIG 300 DC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gys TIG 300 DC in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 3,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info