665744
19
Zoom out
Zoom in
Previous page
1/71
Next page
19
MULTIPEARL 200.2 / 200.4 XL / 201.4
EN
Safety
Arc welding can be dangerous and can cause serious and even fatal injuries. Protect yourself and
others. Ensure the following safety precautions are taken :
Arc radiation: Protect yourself with a helmet tted with lters in compliance with EN169 or EN 379.
Rain, steam, damp: Use your welding unit in a clean/dry environment (pollution factor 3), on a at
surface, and more than one meter from the welding work-piece. Do not use in rain or
snow.
Electric choc: This device must only be used with an earthed power supply, single-phase or three-
phase depending on model. Do not touch the parts under high voltage. Check that the
power supply is suitable for this unit.
Falls: Do not place/carry the unit over people or objects.
Burns: Wear protective (re-proof) clothing (cotton, overalls or jeans).
Wear protective gloves and a re-proof apron.
Ensure other people keep a safe distance from the work area and do not look directly
at the welding arc.
Protect others by installing re-proof protection walls.
Fire risks: Remove all ammable products from the work area. Do not work in presence of
ammable gases.
Fumes: Do not inhale welding gases and fumes. Use the device in a well ventilated environment,
with articial extraction if welding indoors.
Additional Precautions: Any welding operation undertaken in.....
- rooms where there is an increased risk of electric shocks,
- Poorly ventilated rooms,
- In the presence of ammable or explosive material,
Use should always be approved by a «responsible expert», and made in presence of
people trained to intervene in case of emergency.
Technical protection as described in the Technical Specication CEI/IEC 62081 must be
implemented. Welding in raised positions should not be undertaken, except in case of
safety platforms use.
People wearing Pacemakers are advised not to use this machine, however if necessary, please seek
medical advice prior to use. Do not use the welding unit to unfreeze pipes. Handle gas bottles with
care - there is increased danger if the bottle or its valve are damaged.
TROUBLESHOOTING
SYMPTOMS POSSIBLE CAUSES REMEDIES
MIG/MAG
The welding wire
speed is not constant.
Cracklings block up the opening.
Clean out the contact batch or change it and replace the
anti-adherence product. Ref.041806
The wire skids in the rollers.
Control the roller pressure or replace it.
Wire diameter non-consonant with roller.
Covering Wire guide in the torch non-consonant.
The unwinding motor
doesn't operate.
Reel or roller brake too tight. Release the brake and rollers.
Electrical supply problem. Check that the running button is on the position on.
Bad wire unwinding. Covering wire guide dirty or damaged. Clean or replace
Reel brake too tight Release the brake
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gys MULTIPEARL 200-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gys MULTIPEARL 200-2 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 3,96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info