GYSFLASH 30-24 HF
EN
Voltage adjustment
After selected the battery voltage, it is possible to adjust the voltage by 0.1V step according to manufacturer’s specications.
DIAG+ MODE CONFIGURATION
6.0V
6.1V
...
7.4V
DIAG+
U=13.5V
12V
DIAG+
U=27.2V
24V
DIAG+
U=13.5V
12V
6V
12V
24V
12.0V
12.1V
...
14.8V
24.0V
24.1V
...
29.6V
Start up :
• Connect the clamps : red to the (+) and black to
the (-) of the battery.
• Push the START/STOP key to start the mode.
• During use the current consumed and the instan-
taneous voltage are displayed.
STARTING DIAG+
I=12A
DIAG+
U=13.5V
DIAG+
U=13.5V
12V 12V
Precaution: Before using the Diag+ Mode. If the screen displays a current greater than 10A, it indicates the battery is discharged.
The device will start charging automatically Check all electrical consumers are switched off on the vehicle. Wait until the current falls
below 10A and then re-launch the diagnostic.
SHOWROOM MODE
On a stationary vehicle, the charger supplies up to 30A (and 15A in 24V) to test high-energy consumers (engine fan, window regu-
lator, electronic suspension, etc…) by supplying a steady voltage adjustable:
- 12V to 14.8V (for 12V battery)
- 24V to 29.6V (for 24V battery)
- 6V to 7.4V (for 6V battery)
Voltage adjustment:
After selected the battery voltage, it is possible to adjust the voltage by 0.1V step according to manufacturer’s specications.
SHOWROOM MODE CONFIGURATION
6.0V
6.1V
...
7.4V
SHOWROOM
U=13.5V
12V
U=27.2V
24V
U=13.5V
12V
6V
12V
24V
12.0V
12.1V
...
14.8V
24.0V
24.1V
...
29.6V
SHOWROOM
SHOWROOM
Start up with battery :
• Connect the clamps : red to the (+) and black
to the (-) of the battery.
• Push the START/STOP key to start the mode.
• During use the current consumed and the ins-
tantaneous voltage are displayed.
STARTING SHOWROOM
SHOWROOM
13.5V
I=12A
SHOWROOM
U=13.5V
12V12V
Start without battery (not recommended)
Possibility to launch the mode without the battery by pressing the START/STOP key for 3 seconds.
The indictation « no battery » displays for 1 second before supplying the power.
Warning: polarity reversal can damage the vehicle electronics.
Precaution
Before using the Showroom Mode. If the screen displays a current higher than 10A, it indicates the battery is discharged. The device
will start charging automatically. Check all electrical consumers are switched off on the vehicle. Wait until the current falls below 10A
before using any electical functions of the car.
CHANGE BATTERY MODE
This charger will maintain a stabilised power supply to the vehicle during battery replacement to preserve memory settings. By default
this mode is inactive and doesn’t appear in the mode list. It can be activated via the Advanced menu (see page 16).
Voltage selection
It can be set to operate on 6V, 12V or 24V for changing the battery :
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gys GYSFLASH 30-24HF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gys GYSFLASH 30-24HF in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 2,89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info