Any damaged or disposed electric
or electronic devices must be
delivered to appropriate collection
centres.
Package:
Protect against humidity This side up
Residual risks and protective measures
Electric residual risks
Threat Description Protective measure(s)
Direct
electric
contact
Electric shock Safety switch against FI stray
current
Indirect
electric
contact
Electric shock
through
medium
Safety switch against FI stray
current
Disposal
Instructions for disposal arise from icons placed on the
appliance or its package. The description of individual
meanings can be found in the “Marking on appliance“.
Requirements for operating staff
The operating staff must carefully read the Operating
Instructions before using the appliance.
Qualification: Apart from the detailed instructions by a
professional, no special qualification is necessary for
appliance using.
Minimum age: Persons over 16 years of age can only work
on the appliance.
An exception includes youngsters trained in order to reach
knowledge under supervision of the trainer during
occupational education.
Training: Using the appliance only requires corresponding
training by a professional or the Operating Instructions. No
special training is necessary.
Technical data
GSX 1100
Voltage 230 V/50 Hz
Motor capacity P1 1100 W/P1
Maximum immersion 8 m
Maximum delivered quantity 13000 l/h
Maximum head of delivery 9 m
Max. suction 30 mm
Hose connection 1“- 1 ½“ IG
Protection class IP X8
Water temperature 35 °C
Weight ca 6,6 kg
Order Nr. 94625
Transport and storage
At winter storing, it is necessary to make sure there is no
water in the appliance as the frost could damage the
appliance. Prior to transportation, it is necessary to unplug
the pump from the grid! The device has to be completely
emptied and stored with frost-proof protection. Adhesion of
mechanical seals can be prevented if you rinse the pump
with appropriate oil (for example, with vegetable oil).
Assembly and first putting into
operation
Screw the required hose connector (picture F) on the pump or
clamp it (truncate it to the desired connector diameter). Mount
the hose onto the connector and fasten it with a proper hose
clip or coupling.
Caution The shorter the hose is the higher transport output it
provides.
Safety instructions for first putting into operation
Attention: The pump must not run without fillings.
Do not use the pump for drinking water!
The user is responsible to third parties if pump (pumping
station, etc.) is used.
Before putting into operation, a competent electrician must
check whether electric safety devices are in place.
Electric connection to a socket.
Check the voltage. Technical data given on the type label
must correspond with electric network voltage.
If the pump is used in ponds, wells, etc. and appropriate pumping
stations, standards valid for pumps in the given country must
unconditionally be observed.
If the pump is installed in a manhole has one, then close
the manhole with a lid to ensure the integrity of the
passers-by.
The attachment of the outlet pipe is attached to suitable
(Pic. F).
The max. Depth (see meet specifications).
In sandy or muddy bottom, it is necessary to run the
pump on a rope or chain hanging to run or to set up
the pump on an appropriate substrate, to avoid
sinking to the suction part.
In the event of a leak of the oil tank, it is possible
that the contaminated water is contaminated.
Connecting cable for drowned pumps
The drowned pumps are equipped with a 10-m H07RNF
cable, depending on the type.
According to the valid regulation, drowned pumps with a
connecting cable length of less than 10 m can only be used
indoors for water drainage from cellars.
Therefore the cable length and type need to be considered at
purchasing.
Procedure:
Attention!
Important information for the customer
It is recommended to plunge or put the pump sideways in
the liquid. The body air cushion can thus be released and
the pump starts immediately working. The pump can
subsequently be stood straight.
Attention!
Important information for the customer
To ensure long service life of the pump seal, we
recommend rinsing the pump with clean water in regular
intervals.
Automatic float
The float will automatically put the pump into operation when
the liquid level goes up or down. If the float cable is extended
or shortened, based on its support point, it will switch the
pump on or off due to the minimum or maximum height
required. The float cable is fixed to the pump handle with a
suitable pressure holder. Please check whether the float is
moving freely at pump operation. The pump must always be
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gude GSX 1100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gude GSX 1100 in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 0,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info