628271
8
Zoom out
Zoom in
Previous page
1/37
Next page
GB
Please read carefully the following Operating Instructions before putting the appliance into operation
A.V. 2 Any reprints, even partial, are subject to approval. Technical changes reserved.
Illustrative pictures! Translation of original operating instructions.
GB
Do you have any technical questions? Any claim? Do you need any spare parts or operating instructions?
We will quickly help you and without needles bureaucracy at our web pages at www.guede.com in the Servicing part. Please help us be able
to help you. In order to identify your device in case of claim we need the serial No., product No. and year of production. All this data can be
found on the type label. Please enter it here for future reference:
Serial No.: Order No.: Year of production:
E-Mail: support@ts.guede.com
Appliance
Submersible pump made of high-grade steel with an impeller
of high-grade steel, mechanical seal, float automatics, 10
meters of feeder cable, including a universal hose connection
1“ to 1 ¼“.
La livraison et la description des terminaux (pic. A)
1. Carrying handle
2. Pump connection
3. Electric cable
4. Foot
5. Connecting neck of the pump
6. Floating switch
7. Pump cover/body
Use in accordance with designation
The pump is intended exclusively for the purpose of supplying
a house, garden, farm or agricultural facilities with water.
Noncompliance with provisions defined by generally valid
regulations as well as those stipulated in this manual render
the manufacturer of this device unaccountable for any
damage. The service manual has to been read as a whole
prior to the first use of the device. If you feel concerned about
the connection or handling of the device, please turn to the
manufacturer for help.
DE
EU Declaration of Conformity
We,
Güde GmbH & Co. KG
Birkichstraße 6
74549 Wolpertshausen
Germany
hereby declare the conception and construction of the below-
mentioned appliances correspond - at the type of construction being
launched - to appropriate basic safety and hygienic requirements of
EC Directives.
In case of any change to the appliance not discussed with us
the Declaration expires.
Marking of appliances: Dirty-water submersible pump GSX 1100
Order No.: 94625
Date/producer signature: 15.01.2009
Signed by: Mr Arnold, Managing Director
Technical documentation: J. Bürkle FBL; QS
Appropriate EU Directives:
2006/42 EG
2006/95 EG
2004/108/EG
Harmonised standards used:
EN 60335-1:2002+A1+A11+A12+A2
EN 60335-2-41:2003+A1:2004
EN 50366:2003+A1
EN 55014-1:2006
EN 55014-2:1997+A1
EN 61000-3-2-1:2006
EN 61000-3-3:1995+A1+A2
ZEK 01.1-08/06.08
Certification place:
TÜV Rheinland Product Safety GmbH, Am Grauen Stein,
D-51105 Köln, Germany
Guarantee
Guarantee claims as per guarantee card attached.
The manufacturer cannot be held responsible for
damages incurred in consequence of unqualified
installation or unskilled handling of the pump. The device
has to be checked on a regular basis to ensure perfect
functioning. The pump has to be visually checked in
advance of every operation initiation to identify potential
defects (especially the feeder cable and socket plug). It is
strictly forbidden to use a damaged pump.
General safety instructions
TO ENSURE HIGH SAFETY LEVEL, FOLLOW
CAREFULLY THE FOLLOWING INSTRUCTIONS:
Use the device after you have familiarized yourself
thoroughly with the instructions.
Abide by all the safety measures stated in the service manual.
Act responsibly toward third parties.
The pump is not suited for long-run operation (e.g. as
a circulation pump in ponds or streams). When used in
this manner, its service life is curtailed correspondingly.
In these cases, then, use a time switch to secure
sufficient idle periods between cycles of operation.
The pump must not be connected to the existing
water-supply network as a pressure-boosting device.
The pump is not fit to serve either as a permanent,
automatic safety “fuse” against water-tank or water-well
overflow or to regulate underground water in cellar areas.
Do not leave the pump unattended while in operation
in order to prevent subsequent damages caused by
eventual malfunctions. Make sure to disconnect the
device from the grid if you do not plan on using it.
Attention: Operation is only allowed with a safety
switch against stray current (max. stray current of 30mA
according to VDE regulation, part 702). Please ask your
electrician.
Attention: The pump must not in any case run without
fillings.
The user is responsible to third parties if pump (dumping
stations, etc.) is used.
Operate it only on connections with a safety switch
against stray current (FI)!
Before putting into operation, a qualified electrician must
check whether electric safety measures required are in
place.
Electric connection to a socket.
Check the voltage. Technical data given on the type label
must correspond with electric network voltage.
If the pump is used in ponds, wells, etc. and appropriate
pumping stations, standards valid for pumps in the given
country must unconditionally be observed.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gude GSX 1100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gude GSX 1100 in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 0,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info