rinsed with clean water when used in very dirty water. The
switching on and off heights can differ.
Thermal fuse/engine protection circuit-breaker
The drowned pump is equipped with an engine protection
circuit-breaker. If the engine is overheated, the engine
protection circuit-breaker will automatically switch the pump
off. Cooling time is app. 25 minutes, the pump subsequently
switches on. If the engine protection circuit-breaker switches
on, it is absolutely necessary to identify the cause and
remove it (see also the “Failure searching“). The given data
cannot be used for “family style“ repairs as it requires
specific professional knowledge. You must contact the
customer service department at any failures.
Instructions step by step
Connect the water hose to appropriate pump outlet (see
the Assembly and first putting into operation).
Fix the rope, chain, etc. to the pump handle and place it
to the right place.
Put the pump “sideways“ (pic. D) to the pumped
medium. Make sure the floating switch is in the operating
position.
Plug in the pump.
Rinse the pump with clean water after work finishing.
Operation
The pump is put into operation when the plug is inserted in
appropriate socket and the floating switch is in the required
position (see the Instructions). If the pump is lifted or
transported, it is done with an assembled handle and not with
the connecting cable. If the pump is being plunged, a rope,
chain, etc. fastened to the handle need to be used if
necessary.
At muddy, sandy or siliceous soil the pump must be hung on
a rope or chain or put on a suitable wide baseplate to be able
to work plunged. Sand and other abrasive solids reduce the
service life of hydraulic parts and seal of the pump and
therefore they need to be prevented. In frost conditions, the
pump must be removed from the pumped liquid. It is
necessary to absolutely make sure the pump is not exposed
to a risk of frost. The pump must be emptied and stored at a
place protected against frost.
Floating switch positions (pic. B + C)
The operating or shutdown point of the pump can be set
with various floating switch positions. In pic. B you can see
the float cable without any fixation change with full switch
radius. The figure 1 is the working position and figure 0 the
shutdown position.
Due to appropriate fixation of the float cable, possible on the
pump handle, the switch radius can be reduced when there is
no sufficient space or at a corresponding level control. The
figure 1 in pic. C is the working position and figure 0 the
shutdown position.
Continuous operation: The floater can be hung to the side
of the pump; in this position (the floater cable points
downward), the pump runs constantly.
Important: In case of continuous operation, under no
circumstances allow the operation of the pump without
fill!
Important: If the pump is to stay out of service for a longer period of time, make sure by all means necessary that both the
pipelines and the pump itself are emptied. Protect the device against frost. The pump can only be stored entirely empty.
Failures – causes - removal
Failures Causes Removal
Engine does not start
No system voltage
Blocked pump wheel
Floating switch in shutdown position
Check the voltage
Inspect the pump wheel for foreign objects
Check the water level (pic. B/C)
Pump does not suck
Pump without water
Water level too low
Blocked pump wheel
Let the air bubbles release (pic. D)
Switch the pump off, water level must go up.
Remove the obstruction
Insufficient amount of
water pumped
Dirty tube filter
Water level quickly going down
Maximum head of delivery exceeded
Transport guide broken
Clean the tube filter
Ensure sufficient inflow
Check the transport path length
Check the transport guide
Thermal detector
switching the pump off
Dirty tube filter
Water temperature too high
Pump running continuously at maximum pressure.
Clean the tube filter and let the pump cool down
Reduce the water temperature
Make more breaks
Inspections and maintenance
Be sent with the exception of cases described below, the pump for repairs required for service.
Safety instructions for inspections and maintenance
It is always necessary to interrupt feeding (plug pulled out of socket) and make sure the pump is not going to start before any pump
maintenance.
Only a regularly maintained and treated appliance can serve as a satisfactory aid. Insufficient maintenance and care can lead to
unforeseen accidents and injuries.
Inspection and maintenance plan
Time interval Description Any other details
As needed Cleaning and rinsing out Function check of the floating switch (C/D)
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gude GSX 1100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gude GSX 1100 in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 0,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info