626489
10
Zoom out
Zoom in
Previous page
1/120
Next page
7
Display and setting of carbonate hardness on cooler/
carbonator, see table column B on fold-out page IV and
Fig. [27].
c button for carbonate hardness adjustment:
• Press the c button once:
The display switches from the remaining filter capacity to the
value currently set for the carbonate hardness.
• Keep the c button pressed:
After approx. 3 seconds, the value currently set for the
carbonate hardness starts to flash.
• Release the c button within the next 10 seconds:
The value currently set for the carbonate hardness starts
to flash.
• Press the c button and select the required value:
- C1: carbonate hardness 25 - 35 (bypass 20%)
- C2: carbonate hardness 18 - 24 (bypass 30%)
- Factory setting:
C3: carbonate hardness 14 - 17 (bypass 40%)
- C4: carbonate hardness 12 - 13 (bypass 50%)
- C5: carbonate hardness 10 - 11 (bypass 60%)
- C6: carbonate hardness 7 - 9 (bypass 70%)
Press and hold the c button at the required value
for 3 seconds:
The display of the value switches from flashing to
continuous illumination and the value is set.
• Release the c button:
The remaining filter capacity is displayed again:
The litre capacity of the cartridge varies according to the water
hardness set and the size of the cartridge, see table on
fold-out page IV.
The cooler/carbonator of the GROHE Blue
®
fitting is set for
operation with the 600 litre filter cartridge (Prod no.: 40 404)
at the factory.
For operation with the 3,000 litre filter cartridge (Prod. no.: 40 412)
or 1,500 litre filter cartridge (Prod. no.: 40 430), the cooler/
carbonator must be adapted.
Set the filter size, see Fig. [27].
U button for filter size selection:
• Press U button once.
The display switches from the remaining filter capacity to the
value currently set for the filter size.
• Keep the U button pressed:
After approx. 3 seconds, the value currently set for the filter
size starts to flash.
• Release the U button within the next 10 seconds:
The value currently set for the filter size starts to flash.
• Press the U button and select the filter size:
- F1: 600 litres
- F2: 1,500 litres
- F3: 3,000 litres
Press and hold the U button at the required value
for 3 seconds:
The display of the value for the filter size switches from
flashing to continuous illumination and the filter size is set.
• Release the U button:
The remaining filter capacity is displayed again:
The fitting with cooler/carbonator is now fully installed and
ready for operation.
Note: The various filter cartridges can be ordered at
www.grohe.com.
Maintenance
Resetting filter capacity after changing filter cartridge, see
fold-out page IV, Fig. [27].
button for filter replacement reset:
The remaining filter capacity is displayed:
• Press button
The display switches from the remaining filter capacity to rF.
• Keep the button pressed:
After approx. 3 seconds, rF starts to flash.
• Release the button within the next 10 seconds and press
again:
rF flashes first and then illuminates continuously.
• Release the button:
The remaining filter capacity is reset and then displayed
again.
Restore factory settings, see Fig. [27].
Reset Uc buttons to factory settings:
• Press the Uc buttons simultaneously:
The display switches from the remaining filter capacity
to PA.
• Keep the Uc button pressed:
After approx. 3 seconds, PA starts to flash.
• Release the Uc buttons within the next 10 seconds:
First PA flashes, HC lights up and fitting and cooler/
carbonator must be synchronised with one another.
Close handle and wait until the display in the handle
illuminates green.
Open handle fully until display in handle flashes green and
water runs.
• Close handle.
The remaining filter capacity is displayed:
Important:
Risk of damage:
Always disconnect the power supply and interrupt the
CO
2
supply before carrying out maintenance work on the
system. The plug-in connector can then be disconnected,
see fold-out page III, Fig. [24].
Inspect and clean all components and replace if necessary.
I. Cartridge, see fold-out page IV, Fig. [29].
Assemble in reverse order. When installing the cartridge,
ensure that the seals are correctly seated. Replace screw
coupling and tighten.
II. Headpart, see fold-out page IV, Fig. [30].
Assemble in reverse order. Note the installation position of the
stop and cable.
III. Mousseur (64 374), see fold-out page I.
Assemble in reverse order.
IV. Cleaning cooler/carbonator
For hygiene reasons, the cooler/carbonator must be cleaned
once a year. Cleaning must be performed before changing the
cartridge, in order to prevent contamination of the replacement
filter cartridge.
Note: The cleaning kit (Prod. no.: 40 434) can be ordered at
www.grohe.com.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Grohe Blue Chilled and Sparkling system at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Grohe Blue Chilled and Sparkling system in the language / languages: All languages as an attachment in your email.

The manual is 4,57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Grohe Blue Chilled and Sparkling system

Grohe Blue Chilled and Sparkling system Installation Guide - English - 42 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info