30121
24
Zoom out
Zoom in
Previous page
1/56
Next page
Code 34 Code 13 Code 14
DR/EX Switch DUAL RATE EXPONENTIAL
Dual Rate / Exponential Switch Allocation Adjustable Servo Throw Reduction Progressive Control Characteristics
24
D
R
2
3
4
E
X
2
3
4
S
W
I
9
9
9
9
9
9
The switches for the dual-rate and exponential
functions are allocated using code 34. In doing so it is
possible to trigger several control functions
simultaneously without using multi-function switches.
Due to the possibility of reversing switch functions via
the DEC key, dual-rate and exponential can be
coupled with ant other function switch.
Allocation and reversing of external switches
After calling the designations of the control functions
will appear in the upper line of the display for dual-
rate and exponential, with the allocated switches
concerned in the lower line. The small arrow in the
upper line indicates whether the allocation for dual-
rate or exponential is being performed, and it’s
position can be changed using the INC and DEC
keys.
Allocation of the switches is performed by pressing
the key for the input function ( 2 4 ) followed by the
switch number, if necessary pressing DEC first to
reverse the switch polarity.
After all allocations have been made, press ENTER
to store the settings.
Using code 73, switch position, the number and
orientation of the switches can be found quickly and
reliably.
D
U
A
L
R
A
T
E
p
u
s
h
c
h
k
e
y
2
-
4
The dual-rate function permits in-flight switching of
control characteristics, with the range of adjustment
being variable between 0 125% of the normal range
for each of the two switch positions. The switched
must have been allocated beforehand using code 34.
Dual rate refers directly to the corresponding stick
function, independent of whether it affects a single
servo or, optionally via complex mixing and coupling
functions, several ones.
After calling code 13 the desired control functions can
be selected via keys 2 4 :
2 = Ailerons
3 = Elevator
4 = Rudder
Adjustments of the control curve are performed using
the INC and DEC keys after the switch has been
moved to the appropriate position (P0/P1).
E
X
P
O
N
E
N
T
I
A
L
p
u
s
h
c
h
k
e
y
2
-
4
Exponential control permits obtaining sensitive control
of a model near the neutral position of the function
concerned, whilst maximum travel remains
unaffected. The degree of progression can be
adjusted from 0 to 100%, with 0 corresponding to
normal linear travel.
The three control functions ailerons, elevator and
rudder can be switched from linear to progressive
control using switches, which have been allocated by
code 34 beforehand, or from one progressive
adjustment to another progressive one.
These adjustments refer directly to the corresponding
stick function, no matter whether it affects a single
servo or, optionally via complex mixing and coupling
functions, several ones.
After calling code 14 the desired control functions can
be selected via keys 2 4 :
2 = Ailerons
3 = Elevator
4 = Rudder
Adjustments of the control curve are performed using
the INC and DEC keys after the switch has been
moved to the appropriate position. (P0/P1)
In some cases linking the two functions of dual-rate
and exponential may make sense. This is achieved
by using the same switch when allocating the dual-
rate and exponential switches using code 34.
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Graupner MC18 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Graupner MC18 in the language / languages: English as an attachment in your email.

The manual is 7,71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Graupner MC18

Graupner MC18 User Manual - German - 188 pages

Graupner MC18 User Manual - French - 58 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info