GMC-I Messtechnik GmbH 7
7 Characteristic Values
1)
As related to scale length
Scale lengths: R1 l = 46 mm
R2 l = 71 mm
R3 l = 80 mm
Ω l = 67 mm
Ul = 66 mm
2)
Within the marked area of the respective scale (nominal range of use)
Nominal Conditions of Use
Temperature 0 ... 40 °C
Positioning horizontal or vertical
Battery Voltage 7 ... 10 V
Measuring
Function
Measuring Range
Inherent Deviation
at Reference
Conditions
1)
Measuring
Error
2)
Nominal
Voltage
U
N
Nominal /
Measuring
Current
Open-Circuit
Voltage U
o
Frequency /
Short-Circuit
Current I
k
Internal
Resistance
R
i
Switching Value
for Resistance
Overload Capacity
Value Duration
1000 V 0 ... 1000 V ± 2.5%
DC /
40 ... 200 Hz
900 kΩ 1200 V continuous
R1, R2, R3
U
N
= 50 V
0 ... 40 kΩ
± 1.5%
± 25%
of reading
50 V
I
N
1.0 mA
60 V
<12mA
30 kΩ
> 100 kΩ 1200 V max. 10 s20 kΩ ... 1 MΩ 10 kΩ
200 kΩ ... 20 MΩ 40 kΩ
R1, R2, R3
U
N
= 100 V
0 ... 80 kΩ
± 1.5%
± 25%
of reading
100 V 120 V
60 kΩ
> 200 kΩ 1200 V max. 10 s40 kΩ ... 2 MΩ 20 kΩ
400 kΩ ... 40 MΩ 80 kΩ
R1, R2, R3
U
N
= 250 V
0 ... 200 kΩ
± 1.5%
± 25%
of reading
250 V 300 V
150 kΩ
> 500 kΩ 1200 V max. 10 s100 kΩ ... 5 MΩ 50 kΩ
1 MΩ ... 100 MΩ 200 kΩ
R1, R2, R3
U
N
= 500 V
0 ... 400 kΩ
± 1.5%
± 25%
of reading
500 V 600 V
300 kΩ
> 1 MΩ 1200 V max. 10 s200 kΩ ...10 MΩ 100 kΩ
2 MΩ ... 200 MΩ 400 kΩ
R1, R2, R3
U
N
= 1000 V
0 ... 0.8 MΩ
± 1.5%
± 25%
of reading
1000 V 1200 V
600 kΩ
> 2 MΩ 1200 V max. 10 s400 kΩ ... 20 MΩ 200 kΩ
4 MΩ ... 400 MΩ 800 kΩ
4 Ω 0 ... 4 Ω± 1.5%
± 10%
of reading
I
m
200
mA
9 V > 200 mA 0.315 A continuous
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRISO 1000A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRISO 1000A in the language / languages: English as an attachment in your email.

The manual is 0,26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info