24 GMC-I Messtechnik GmbH
Response Time (after manual range selection)
Display
LCD window (95 mm x 40 mm) with analog and digital display, including display
of unit of measure, current type and various special functions.
Type
COG (chip on glass) for good legibility from various directions
Background Illumination
Background illumination (by means of LEDs) is activated with two keys, and is
switched off automatically after approximately 1 minute.
Analog:
Display LCD scale with pointer
Scale length 80 mm for V and A ;
67 mm for all other ranges
Scaling 5
0 30 with 35 scale graduations for ,
0 ... 30 with 30 scale graduations for all other ranges
Polarity Display with automatic switching
Overload Display triangle appears
Sampling Rate 20 measurements per second
Digital:
Display/Char. Height 7 segment characters / 20 mm
Number of Places 4¾-place 31000 steps
Overload Display 0L” appears
Polarity Display –” is displayed if plus pole is connected to jack
Sampling Rate 2 measurements per second
Display Refresh Rates
V (DC), V~ (AC), A, , ,
C (Pt100, Pt1000) twice per second
Hz once per second
Power Supply
Batteries 2 ea. 1.5 V cells (4 x AA size)
alkaline-manganese per IEC LR6
Measured Quantity /
Measuring Range
Digital Display
Response Time
Measured Quantity
Jump Function
V , V ~,
A, A~
1.5 s
from 0 to 80%
of the measuring range upper limit
30 3M 2s
from to 50%
of the measuring range upper limit
30 M 5s
Continuity < 50 ms
1.5 s
C (Pt100/Pt1000) max. 3 s
30 nF 300 F max. 2 s
from 0 to 50%
of the measuring range upper limit
>10 Hz max. 1.5 s
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRAport 40S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRAport 40S in the language / languages: English as an attachment in your email.

The manual is 0,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info