V/Hz, Ω, Temperature, and A/Hz Measurements
5.7 Current Measurement
Notes Regarding Current Measurement
The multimeter may only be operated with installed batteries or re-
chargeable batteries. Dangerous currents are otherwise not indicated,
and the instrument may be damaged.
Set up the measuring circuit in a mechanically secure fashion, and
secure it against inadvertent breaks. Select conductor cross-sec-
tions and lay out connections such that they do not overheat.
An intermittent acoustic signal warns of current greater than 10 A.
An continuous acoustic signal warns of current greater than 16 A
.
When measuring high current values, limit them to max. 16 A for
30 seconds or 10 A for max. 5 minutes, and allow the multimeter
to cool down for 10 minutes between measurements.
For purposes of orientation, internal temperature in close prox-
imity to the jacks is displayed at the right-hand auxiliary display
in the 3 A and 10 A or 16 A ranges. If temperature rises to
above 50° C, you are warned by an intermittent acoustic sig-
nal.
The input for the current measuring range is equipped with a
fuse link. Maximum permissible voltage for the measuring cir-
cuit (= rated voltage of the fuse) is 600 V AC/DC. Use specified
fuses only! The fuse must have a breaking capacity of at least
30 kA.
If the fuse for the active current measuring range blows,
FUSEappears at the digital display, and an acoustic signal is
generated at the same time.
If a fuse should blow, eliminate the cause of overload before
placing the instrument back into service!
Fuse replacement is described in section 9.3.
Be absolutely certain that the measuring ranges are not over-
loaded beyond their allowable capacities. Limit values are in-
cluded in section 8, “Technical Data”, in the table entitled
“Measuring Functions and Measuring Ranges” in the “Over-
load Capacity” column.
*Scope of Functions, Current Measurement, Direct Connection
Scope of Functions, Current Measurement with Current Clamp Sensor
Scope of Functions, Current Measurement with Current Clamp Transformer
Function Switch Position Measuring Range
Transformation ratio SEt menu, CliP=OFF
A DC A
300 μA
3 / 30 / 300 mA
3 / 10 A (16 A)
A AC+DC TRMS
/ Hz (A AC) A
A AC / Hz (A AC) ~ A~
Hz (A AC+DC) /
A AC+DC TRMS
A
Up to 30 kHz
Hz (A AC) / A AC ~ Hz
Function Switch Position
Transformation ratio SEt menu, CliPOFF
A DC V
A AC+DC / Hz (A AC) V
Hz (A AC) / A AC+DC Hz
A AC / Hz (A AC) V~
Hz (A AC) / A AC Hz
Function Switch Position
Transformation Ratio SEt menu, CliPOFF
A DC A
A AC+DC / Hz (A AC) A
Hz (A AC) / A AC+DC A
A AC / Hz (A AC) A~
Hz (A AC) / A AC Hz
42


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRAHIT ULTRA BT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRAHIT ULTRA BT in the language / languages: English as an attachment in your email.

The manual is 0,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info