590625
43
Zoom out
Zoom in
Previous page
1/74
Next page
GMC-I Messtechnik GmbH 43
V/Hz/dB – Ω, Temperature, and A/Hz Measurements
5.7.1 Direct and Pulsating Current Measurement, Direct Connection, A
DC and A (DC+AC)
Ð First disconnect supply power from the measuring circuit or
the power consumer, and discharge any capacitors.
Ð In accordance with the current to be measured, set the rotary
switch to A or A .
Ð Select the type of current appropriate for the measured quan-
tity by briefly pressing the multifunction key FUNC | ENTER. Each
time the key is pressed, the instrument is switched back and
forth between A DC and A (DC + AC)
TRMS
, which is indicated
by means of an acoustic signal. The current type is indicated at
the LCD by means of the DC or the (DC+AC)
TRMS
symbol.
Ð Safely connect the measuring instrument (without contact re-
sistance) in series to the power consumer as shown.
Ð Switch supply power to the measuring circuit back on.
Ð Read the display. Make a note of the measured value if the in-
strument is not being operated in the memory mode or the
transmission mode.
Ð Disconnect supply power from the measuring circuit or the
power consumer once again, and discharge any capacitors.
Ð Remove the test probes from the measuring point and return
the measuring circuit to its normal condition.
Ð Direct frequency measurement, A (DC + AC)
TRMS
(see follow-
ing section).
COM mA A
~
R
x
~
R
x
1
3
2
I > 10 A
!
A
A
300 μA / 3 mA
30 mA / 300 mA
3 A / 10 A (10 A max. 5 min)
8
.
8
.
8
.
8
.
8
!
I > 16 A
Current
Measuring Ranges:
Current measurement
may only be performed
with installed batteries!
*
Additional temperature display
(internal temperature at jacks)
in the 3 A and 10 A ranges
(16 A max. 30 s)
002.500
A
DC
002.50
A
DC
AC
TRMS
A
A
FUNC
ENTER
24. C
*
24. C
*
015
.
000
Hz
Hz
43


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRAHIT ULTRA BT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRAHIT ULTRA BT in the language / languages: English as an attachment in your email.

The manual is 0,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info