590626
18
Zoom out
Zoom in
Previous page
1/28
Next page
18 GMC-I Messtechnik GmbH
15 Characteristic Values
Measuring
Function
Measuring Range
Resol. at Meas. Range Upper Limit
1200 000
1)
120 000
1)
12 000
1)
V
100 mV 0.1 μV1μV10μV
1V 1μV10μV 100 μV
10 V 10 μV 100 μV1mV
100 V 100 μV1mV10mV
600 V 1 mV 10 mV 100 mV
mA
100 μA 100pA 1nA 10nA
1 mA 1 nA 10 nA 100 nA
10 mA 10 nA 100 nA 1 μA
100 mA 100 nA 1 μA10μA
Ω
100 Ω 0.1 mΩ 1mΩ 10 mΩ
1kΩ 1mΩ 10 mΩ 100 mΩ
10 kΩ 10 mΩ 100 mΩ 1 Ω
100 kΩ 0.1 Ω 1 Ω 10 Ω
1MΩ 1 Ω 10 Ω 100 Ω
10 MΩ 10 Ω 100 Ω 1000 Ω
Ω
100 Ω 10 mΩ
Resolution
Hz
1Hz
2)
to
100 kHz
0.000 001 Hz
0.1 Hz
Sensor
°C/°F
– 200.0 ... +850.0 °C 0.01 °C Pt100 / Pt1000
210.0 ... + 1200.0 °C
0.1 °C
J (Fe-CuNi)
270.0 ... + 1372.0 °CK (NiCr-Ni)
Input Impedance
V
100 mV > 1 GΩ >1GΩ //<50pF
1V >1GΩ 10 MΩ //<50pF
10 V 10 MΩ 10 MΩ //<50pF
100 V 10 MΩ 10 MΩ //<50pF
600 V 10 MΩ 10 MΩ //<50pF
Approx. Voltage Drop at Meas. Range Upper Limit
mA
100 μA 150 mV 150 mV
1 mA 1.5 V 1.5 V
10 mA 150 mV 150 mV
100 mA 1.5 V 1.5 V
Open-Circuit Voltage
Meas. Current at Meas.
Range Upper Limit
Ω
100 Ω 3V 1mA
1kΩ 3V 1mA
10 kΩ 3 V 100 μA
100 kΩ 3V 10μA
1MΩ 3V 1μA
10 MΩ 3 V 100 nA
Ω
100 Ω 3V 1mA
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRAHIT 30M at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRAHIT 30M in the language / languages: English as an attachment in your email.

The manual is 0,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info