590606
23
Zoom out
Zoom in
Previous page
1/28
Next page
GMC-I Messtechnik GmbH 23
Influencing Quantities and Influence Error
1)
With zero balancing
2)
Specified error valid as of display values of 10% of the measuring range
1)
With zero balancing
Real-Time Clock
Accuracy ±1 minute per month
Temperature Influence 50 ppm/K
Reference Conditions
Ambient
temperature +23° C ±2K
Relative humidity, 40 ... 60%
Measured quantity
frequency 45 ... 65 Hz
Measured quantity
waveshape Sinusoidal, deviation between RMS
and rectified value < 0.1%
Storage battery voltage 3.6 V ±0.2 V
Response Time
Response Time (after manual range selection)
* without parallel capacity
Display
LCD panel (65 mm x 30 mm) with display of up to 3
measured values, unit of measure, type of current and
various special functions.
Display / Char. Height 7-segment characters
Main display: 12 mm
Auxiliary displays: 7 mm
Number of places 4¾ places 30999 steps
Overflow display 0. L“ appears
Polarity display “–” sign is displayed if plus pole
is connected to “
LCD test All display segments available
during operation of the METRA
HIT27 are activated after the
instrument is switched on.
Background illumination METRA HIT 27I only
Influencing
Quantity
Sphere of
Influence
Measured Quantity /
Measuring Range
1)
Influence Error
± (... % rdg. + d)/10 K
Temperature
0 +21 °C
and
+25
+40 °C
V DC 0.1 + 5
V AC 0.5 + 5
mΩ@ 1 A 4L 1 + 5
mΩ@ 200 mA 4L 1 + 5
300 Ω 300 kΩ 2L 0.2 + 5
3MΩ 2L 0.5 + 5
30 MΩ 2L 1 + 5
Insulation 30 M
Ω
3 G
Ω
2 + 5
Hz 0.1 + 5
°C (RTD) 0.5 + 10
Influencing
Quantity
Frequency
Measured
Quantity /
Measuring
Range
Influence Error
2)
± (... % rdg. + d)
Frequency
V
AC
> 20 Hz ... 45 Hz
3V
up to
600.0 V
2 + 10
> 65 Hz ... 1 kHz
Influencing
Quantity
Sphere of
Influence
Measured Quantity /
Measuring Range
1)
Influence Error
Relative
humidity
75%
3 days
instrument off
All measured
quantities
1 x intrinsic
uncertainty
Influencing
Quantity
Sphere of Influence
Measuring
Range
Damping
±dB
Common
Mode
Interference
Voltage
Interference quantity max. 600 V ~ V DC > 90 dB
Interference quantity max. 600 V ~
50 Hz, 60 Hz sine
30 V ~ > 80 dB
300 V ~ > 70 dB
600 V ~ > 60 dB
Series Mode
Interference
Voltage
Interference quantity: V,
respective nominal value
of the measuring range,
max. 600 V ~ , 50 Hz, 60 Hz sine
V= > 60dB
Interference quantity max. 600 V DC V ~ > 60 dB
Measured Quantity /
Measuring Range
Response Time
for Digital Display
Measured Quantity
Step Function
VDC, VAC 1.5s
from 0 to 80%
of upper range limit value
mΩ@ 1 A 4L 2 s
from to 50%
of upper range limit value
mΩ 1.5 s
300 Ω ... 3 MΩ 2s
3GΩ ∗ 5s
Continuity < 50 ms
1.5 s
°C Pt100 max. 3 s
>10 Hz 1.5 s
from 0 to 50%
of upper range limit value
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRA HIT 27I at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRA HIT 27I in the language / languages: English as an attachment in your email.

The manual is 0,51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gossen Metrawatt METRA HIT 27I

Gossen Metrawatt METRA HIT 27I Quick start guide - English, German - 4 pages

Gossen Metrawatt METRA HIT 27I User Manual - Dutch - 28 pages

Gossen Metrawatt METRA HIT 27I Quick start guide - French - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info