13 Characteristic Values
1)
Display: 3¾ places in the range of 3 mΩ@1A, 30 mΩ, , MΩ@...V;
A different sampling rate can be selected in the rAtE menu for saving and
transmitting measured values.
2)
Lowest measurable frequency for sinusoidal measuring signals symmetrical to
the zero point
3)
At 0°…+40° C
4)
ZERO is displayed for “zero balancing” function.
5)
Range 3 V~: U
E
=0.15V
eff/rms
. . . 3 V
eff/rms
30 V~: U
E
=1.5V
eff/rms
. . . 30 V
eff/rms
300 V~: U
E
=15V
eff/rms
. . . 300 V
eff/rms
600 V~: U
E
=30V
eff/rms
. . . 600 V
eff/rms
For voltages > 100 V: power limiting of 1.8 · 10
6
V · Hz
6)
20 45 65 Hz 1 kHz sine, see influences on page 23.
7)
Pulsating measuring current with interval of T = 1 s
8)
Plus sensor deviation
9)
Temperature value is calculated from the characteristic curve per EN 60751
10)
In the event of extremely high resistances the capacitive influence of the person
performing the measurement and/or the measuring cable may distort the
measured value. Use therefore short or shielded measurement cables.
11)
In the event of an overload, the integrated FF1.6A/1000V fuse is triggered.
Key
rdg. = reading (measured value), R = measuring range, d = digit(s), 2/4 L = 2/4-wire connection
Measuring
Function
Measuring Range
Resolution at Upper
Range Limit
Input Impedance
Intrinsic Uncertainty at Max. Resolution
under Reference Conditions
Overload Capacity
3)
±(...% rdg. + ... d) ±(...% rdg. + ... d)
4¾ 30000 / 3¾ 3000
1)
DC AC
6)
DC AC
6)
Value Time
V
3 V 100 μV2.1MΩ 2.1 MΩ // < 50 pF 0.1 + 10
4)
0.2 + 10 (>500d)
600 V
DC
AC
RMS
sine
Cont.
30 V 1 mV 2.1 MΩ 2.1 MΩ // < 50 pF 0.1 + 5 0.2 + 10 (>500d)
300 V 10 mV 2.1 MΩ 2.1 MΩ // < 50 pF 0.1 + 5 0.2 + 10 (>500d)
600 V 100 mV 2.1 MΩ 2.1 MΩ // < 50 pF 0.1 + 5 0.2 + 10 (>500d)
Open-circuit voltage
Meas. current approx.
±(...% rdg. + ... d)
mΩ@1A
(4 L)
3mΩ 0.001 mΩ 3.5 4 V 1 A
7)
1+10
±0.6 V
11)
Cont.30 mΩ 0.001 mΩ 3.5 4 V 1 A
7)
0.5 + 10
300 mΩ 0.01 mΩ 3.5 4 V 1 A
7)
0.5 + 10
mΩ
(4 L)
30 mΩ 0.01 mΩ 3.5 4 V 200 mA
0.25 + 10
±0.6 V
11)
4)
Cont.
300 mΩ 0.01 mΩ 3.5 4 V 200 mA
3 Ω 0.1 mΩ 3.5 4 V 20 mA
30 Ω 1mΩ 3.5 4 V 20 mA
Ω
(2 L)
300 Ω 10 mΩ 3.5 4 V 1 mA 0.1 + 10
4)
600 V
DC
AC
RMS
sine
max. 10 s
3kΩ 100 mΩ 3.5 4 V 100 μA0.1+5
4)
30 kΩ 1 Ω 3.5 4 V 20 μA0.1+5
300 kΩ 10 Ω 3.5 4 V 20 μA0.1+5
3MΩ 100 Ω 3.5 4 V 10 μA0.1+5
30 MΩ 1kΩ 3.5 4 V 10 μA1.5+10
300 Ω 0.1 Ω 3V 1mA 1+5
3V 0.1mV 3V 1mA 1+5
Test Voltage Measuring Current
MΩ@
...V
30 MΩ 0.01 MΩ 50/100/250/500 V
< 1.5 mA
2+10
600 V
DC/AC
max. 10 s300 MΩ 0.1 MΩ 50/100/250/500 V 2 + 10
3000MΩ
10)
1MΩ 50/100/250/500 V 3 + 10
f
min
2)
±(...% rdg. + ... d)
Hz
300 Hz 0.01 Hz
1 Hz 0.05 + 5
5)
600 V AC Cont.
3kHz 0.1 Hz
Temperature
Sensor
Measuring Range Resolution
Intrinsic Error at Max. Resolution under Reference Conditions
±(...% rdg. + ... d)
8)
°C/°F
Pt 100
9)
200.0 +100.0 °C
0.1 °K
1 K + 5
600 V
DC
AC
RMS
sine
max. 10 s
+100.0 +600.0 °C 0.5 + 5
Pt 1000 200.0 +100.0 °C1 K + 5
+100.0 +600.0 °C 0.5 + 5
Ni 100 60.0 +180.0 °C0.5+ 5
Ni 1000 60.0 +180.0 °C0.5+ 5
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRA HIT 27I at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRA HIT 27I in the language / languages: English as an attachment in your email.

The manual is 0,51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gossen Metrawatt METRA HIT 27I

Gossen Metrawatt METRA HIT 27I Quick start guide - English, German - 4 pages

Gossen Metrawatt METRA HIT 27I User Manual - Dutch - 28 pages

Gossen Metrawatt METRA HIT 27I Quick start guide - French - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info