479852
3
Zoom out
Zoom in
Previous page
1/9
Next page
SPECIAL FUNCTIONS
Panic
Is obtained pressing the transmitter 2 button with the alarm armed or disarmed after the neutral
time of 45 seconds. The siren activates for 29 seconds. To de-activate the siren within the 29
seconds, press again on the transmitter 2 button.
SIREN EXCLUSION
While alarm disarmed, turn the ignition key of the vehicle to ON. Press on the transmitter 2 button
for at least 3 seconds, the LED lights fix till the releasing of the transmitter’s button to signal the
siren sound exclusion.
Turn again the ignition key to OFF and arm the alarm system. The disarming of the system sets to
zero the function.
SELF-LEARNING OF THE CODE OF A NEW TRANSMITTER.
1. Disarm the alarm with the transmitter.
2. Set the dip-switch N.6 to ON.
3. Turn the vehicle i gnition key to ON for at least 1 second and then to OFF. The LED lights fix till
the ignition key is turned to OFF.
4. Turn the key to OFF and within 30 seconds press one of the transmitter’s buttons to learn. The
LED lights for 0,5 seconds to signal the code memorisation.
NOTE: If the operation is not carried out within 30 seconds it will be necessary to repeat the
operation from point 3.
It is possible to learn a maximum number of 4 transmitters; for each transmitter’s coding repeat the
operation from point 3.
ATTENTION! AT THE END OF THE PROCEDURE SET THE DIP-SWITCH N.6 TO OFF.
ULTRASONIC SENSOR EXCLUSION AND WINDOWS CLOSURE.
During the first 25 seconds of neutral time, it is possible to de-activate the ultrasonic sensors and to
stop the window closure pressing on the transmitter 2 button. One-direction indicator lights
flashing signals the operation.
If the time set is 1,5 or 6 seconds, the exclusion of the ultrasonic inlet disables the positive outlet on
the alarm Pink wire (+A); to obtain the disabling of the closure relay set the comfort time of 25
seconds.
To exclude the ultrasonic inlet with the windows completely closed; it is necessary to wait the
complete closure of the window and to press on the transmitter 2 button.
ACOUSTIC SIGNAL LING EXCLUSION (CHIRP)
1. While alarm disarmed, turn the ignition key of the vehicle to ON.
2. Press on the transmitter 1 button for at least 3 seconds. The LED flashes for 0,5 seconds to
signal the audible tone exclusion.
3. Position again the vehicle ignition key to OFF.
CHIRP FUNCTION ACTIVATION.
1. While alarm disarmed turn the vehicle ignition key to ON.
2. Press on the transmitter 1 button for at least 3 seconds. The LED flashes for 0,5 second; the
activation of the Chirp function is signalled by one audible tone.
LED’S MEMORY
While alarm disarmed it is possible to verify if an alarm condition has occurred and to determine
the cause following the LED flashing.
LED SIGNALLING ALARM TRIGGERING
Y l Y Ultrasonic sensors inlet
Y Y l Y Y Ignition live (engine immobilisation)
Y Y Y l Y Y Y Door, boot and bonnet pin switch and
absorption sensor.
l LED OFF (2,5 seconds) Y LED ON ( 400mS)
NOTE: to stop the LED flashing it is necessary to turn the ignition key to ON.
ACTIVE FUNCTIONS WHILE ALARM ARMED
IMMEDIATE AFTER 45 SECONDS
- Ignition live: activates while arming the
system; the detection is obtained after the
neutral time of 45 seconds.
- cut wires (art.7203)
- current absorption;
- door, boot and bonnet opening;
- sensors inlet.
NOTE: the neutral time is signalled through the LED lightning fix.
Transmitters battery discharging
The discharging of the battery is signalled through the
LED of the transmitter. If the LED flashes while
pressing one of the transmitter’s buttons it is
necessary to replace the batteries.
Batteries model : CR1616
Note:
put the batteries in the appropriate container.
TECHNICAL DATA
Power supply 12VDC
Current absorption alarm ON with US module 16mA
Current absorption alarm OFF 9 mA
Working temperature -30°+ 85°C
Engine immobilisation relay contact capacity 8A a 20°C
Blinker and central door locking relay contact capacity 10A a 20°C
Power sound at 1 meter in open space > 118dB
Minimum sensitivity absorption sensor 5W
Current for positive control alarm armed 500 mA
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gemini 7201 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gemini 7201 in the language / languages: English as an attachment in your email.

The manual is 1,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info