813412
44
Zoom out
Zoom in
Previous page
1/52
Next page
44
13. Main Injector
To change the main injector:
13.1 Undo the injector feed pipe.
13.2 Undo the lock nut from the injector.
13.3 Replace with the correct size injector.
14. Primary Aeration Plate
NOT ALL MODELS HAVE AERATION PLATES. REFER TO
TECHNICAL SPECIFICATIONS, PAGE 9.
14.1 Remove the burner module as described in Servicing,
Section 6.
14.2 Remove the fixing screw and slide the plate off the venturi.
14.3 Replace with the correct size plate and secure with the
screw. Ensure the lower edge of the plate is located over
the venturi flange, see Diagram 25.
25
15. Changing Between Gas Types
In order to change between gas types it will be necessary
to change both the burner assembly and the complete
control assembly.
Contact your Gazco retailer for further information.
A kit of parts is available for this. Always quote the Model
number and Serial number when ordering any spare parts.
16. Pressure and leak testing
the appliance
16.1 To gain access to the pressure test point, see Diagram 26
follow Section 7, Main Control Assembly.
26
16.2 To leak test any gas joints on the appliance the control
assembly must be undone and tilted backwards, see
Section 7.6, Diagram 18.
16.3 Because there is now no burner fitted to perform a leak
test, place a manometer tube over the injector tip.
16.4 Light the appliance and spray any joints with leak detector
fluid.
16.5 Tighten joints or replace as required.
16.6 To check the inlet working pressure, replace the control
assembly and connect a manometer to the pressure test
point, see Diagram 25.
16.7 Replace the burner and relight the appliance.
16.8 Operate the appliance at highest flame setting and check
that the inlet pressure is in accordance with specifications
detailed on page 9.
44


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Studio Freestanding Balanced Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Studio Freestanding Balanced Flue in the language / languages: English as an attachment in your email.

The manual is 8.63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info