813405
27
Zoom out
Zoom in
Previous page
1/40
Next page
27
SERVICING INSTRUCTIONS
REPLACING PARTS - CONVENTIONAL FLUE
1. GENERAL - CONVENTIONAL FLUE
1.1 All principal components can be replaced without removing
the appliance from its installation, although it is essential
that the gas supply to the appliance is turned off at the
isolation device before proceeding further.
1.2 It will be necessary to remove the complete burner module
before any of the components can be serviced.
2. REMOVE THE BURNER MODULE
2.1 To remove the module:
Remove the decorative front by undoing the screws at the
bottom lift the frame towards you and up (see Diagram 1).
1
AR1824 AR1822
2.2 Remove the glass frame. See Diagram 2, arrow A.
2
AR0748A
2.3 Remove the ceramic logs.
2.4 Remove the granules.
2.5 Carefully slide the side panels forward (see Diagram 3)
and store safely (they are very fragile).
3
AR0759
HAVE YOU ISOLATED THE GAS SUPPLY?
2.6 Disconnect the isolating device from the appliance inlet
pipe so as to leave the gas supply isolated.
2.7 Remove the screws retaining the log support (see Diagram
4).
4
AR0758a
2.8 Remove the two screws at the front of the burner tray
and loosen the screw at the rear (see Diagram 5).
5
AR0767(A)
2.9 Hold the burner tray at the front, pull forward and
rotate upwards. The unit can now be serviced.
2.10 When replacing the unit ensure the location tabs
engage under the divider plate (see Diagram 6).
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Riva F67 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Riva F67 in the language / languages: English as an attachment in your email.

The manual is 4.73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info