Servicing Instructions - Replacing Parts
2.12 Carefully remove the fuel bed and place safely to one side.
2.13 Hold the burner tray at the front, pull forward and rotate
upwards. The unit can now be serviced.
2.14 When replacing the unit ensure the location tabs engage
under the divider plate, see Diagram 6.
6
3. Pilot Unit
3.1 Undo the compression nut on the pilot burner then undo the
thermocouple at the rear of the gas valve. Remove the
ignition lead from the electrode, undo the two retaining
screws and remove the pilot, see Diagram 7.
7
3.2 When replacing the pilot ensure the thermocouple follows its
original route, i.e. along the pilot pipe. Attach the
thermocouple to the pipe with new cable ties.
3.3 Set the spark gap, see Diagram 8.
8
15mm 4mm
3.4 Check for gas leaks.
4. Ignition Lead
4.1 Gain access to the pilot assembly (see Section 2) and
disconnect the ignition lead from the electrode.
4.2 The control box is secured to the bracket with velcro.
Remove the control box from the bracket to ease access to
the ignition lead connection, see Diagram 9.
13
Control Box
Ignition lead
9
4.3 Replace with a new ignition lead following the same route
as the old one. Refit the Vidaflex cover over the ignition
leads. Ensure the cover engages fully over the electrode.
4.4 When replacing the control box ensure no wires are trapped
and check the operation of the new ignition lead.
4.5 Replace the main burner.
5. Gas Valve
To change the gas valve:
5.1 Disconnect the gas inlet pipe, see Diagram 10, Arrow A.
5.2 Disconnect the gas outlet pipe, see Diagram 10, Arrow B.
5.3 Disconnect the pilot pipe, see Diagram 10, Arrow C.
5.4 Disconnect the thermocouple, thermocurrent wires and the
interrupter block, see Diagram 10, Arrow D
5.5 Remove the eight wire loom, see Diagram 10, Arrow E.
C
D
A
B
E
10
5.6 Remove the 2 screws securing the valve to the support
bracket and withdraw the valve.
Replace in reverse order.
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Riva 2 F670 Conventional Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Riva 2 F670 Conventional Flue in the language / languages: English as an attachment in your email.

The manual is 4.52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info