Servicing Instructions - Replacing Parts
1. General
1.1 All main components can be replaced without removing the
appliance from its installation.
IT IS ESSENTIAL THAT THE GAS SUPPLY TO THE
APPLIANCE IS TURNED OFF AT THE ISOLATION
DEVICE BEFORE PROCEEDING FURTHER.
1.2 It will be necessary to remove the complete burner module
before any of the components can be serviced.
2. Main Burner
2.1 Turn the gas supply off at the isolation device.
2.2 Remove the decorative front by lifting to disengage the
fixing hooks from the locating slots, see Diagram 1.
1
2.3 Place carefully to one side.
2.4 Remove the glass frame, see Diagram 2.
2
2.5 Place carefully to one side.
2.6 The glass frame must be refitted to the appliance following
cleaning or servicing. Hold in position and secure with the
screws
2.7 Replace ALL of the securing screws ensuring that a screw is
present in all fixing slots.
UNDER NO CIRCUMSTANCES SHOULD THE
APPLIANCE BE USED IF ANY OF THE GLASS
FRAME RETAINING SCREWS ARE LOOSE OR
MISSING
2.8 Remove the decorative logs.
2.9 Carefully slide the liners forward, see Diagram 3 and store
safely (they are very fragile).
3
HAVE YOU ISOLATED THE GAS SUPPLY?
2.10 Disconnect the isolating device from the appliance inlet pipe
so as to leave the gas supply isolated, see Diagram 4.
Elbow
4
2.11 Remove the 2 screws at the front of the burner tray and the
2 behind the burner fuel bed at the rear, see Diagram 5.
5
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Riva 2 F670 Conventional Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Riva 2 F670 Conventional Flue in the language / languages: English as an attachment in your email.

The manual is 4.52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info