813483
25
Zoom out
Zoom in
Previous page
1/52
Next page
25
Installation Instructions
3.60 Flue Lengths over 5m (Top Exit Only)
If the flue length extends 5m above the appliance a 40mm
Ø restrictor must be fitted. This restrictor can be found in the
appliance packing kit supplied.
3.61 To fit the restrictor undo the bolts on the slide collars on the
restrictor assembly, see Diagram 10.
Restrictor
plate
Screws
10
3.62 Remove the restrictor plate that is current in place and fit the
40mm Ø one from the kit.
Secure with the screws and ensure that the plate moves
freely up and down on the slide collars.
3.63 Fit the restrictor assembly as previous described.
4. Gas Soundness Pressure Check
4.1 Connect a suitable pressure gauge to the test point located
on the inlet fitting and turn the gas supply on. Light the
appliance and check all gas joints for possible leaks. Turn
the appliance to maximum and check that the supply
pressure is as stated on the databadge. Turn the gas off
and replace the test point screw, turn the gas on and check
the test point for leaks.
5. Removing the Door
IMPORTANT: THE OUTER PANELLING OF THE
APPLIANCE IS MADE FROM CAST IRON. USE
CAUTION WHEN INSTALLING, REMOVING AND
STORING AS THE COMPONENTS ARE HEAVY
AND SHOULD BE HANDLED CAREFULLY.
5.1 For rear flue exit lift the top of the appliance off and put to
one side.
5.2 For top flue exit lift and support the top to give clearance,
see Diagram 11.
11
Huntingdon 20 and 40
5.3 Supporting the door top and bottom pull forwards whilst
lifting the front upwards at a 45° angle until it is clear of the
slots and pull away from the appliance, see Diagram 12.
12
Huntingdon 30
5.4 Lift the front upwards until it is clear of the slots and pull
away from the appliance, see Diagram 13.
13
All Models
5.5 Remove the glass frame by undoing the fixing screws and
lifting clear, see Diagram 14. Take care to support the
glass window panel when removing the screws.
14
5.6 Place carefully to one side.
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Huntingdon 20-30-40 - Balanced Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Huntingdon 20-30-40 - Balanced Flue in the language / languages: English as an attachment in your email.

The manual is 3.33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info