Installation Instructions
3.23 Feed the flue through the wall, making sure it runs
smoothly.
On the inside wall:
3.24 Engage the flue in the inner and outer spigots.
3.25 Make sure rubber seals on the spigots are not damaged
From outside:
3.26 Insert 4 screws in the flanges of the flue terminal.
3.27 Check sealant has formed a water-tight joint to the wall.
3.28 Any terminal less than 2m above any access (level ground,
balcony or flat roof with access) must be fitted with the
guard supplied, see Diagram 4.
4
3B. Top Exit - Up & Out
(Huntingdon 30 & 40 only)
3.29 There are two types of top exit flue terminals: vertical and
horizontal (see Site Requirements, Diagram 3, for minimum
and maximum flue lengths).
Decorative Collar
3.30 There is an optional decorative collar, Part No: 8548, to
cover the gap between the top plate and flue.
THIS MUST BE POSITIONED BEFORE INSTALLING THE
FLUE. WHEN INSTALLING A TOP EXIT FLUE, REFER
TO INSTALLATION INSTRUCTIONS, TECHNICAL
SPECIFICATION (PAGE 9) FOR THE APPROPRIATE
SIZE RESTRICTOR.
A restrictor may be required for top exit flues. See
technical specification on page 12 for restrictor size.
Reversing Spigots
3.31 The appliance is factory set for rear exit. For top exit reverse
the spigots and blanking plates, see Diagram 5.
TAKE CARE WHEN MARKING OUT FOR THE FLUE AS
IT IS DIFFICULT TO MOVE AFTER INSTALLATION. IF A
RESTRICTOR IS REQUIRED FIT THIS BETWEEN THE
SMALL OUTLET SPIGOT AND THE AIR DUCT, SEE
DIAGRAM 5. REFER TO TECHNICAL SPECIFICATIONS
FOR RESTRICTOR SIZE.
5
3.32 REMEMBER TO FIT THE OPTIONAL DECORATIVE
COLLAR IF REQUIRED.
Wall Plate
3.33 A wall plate is supplied to secure the flue to the inside wall.
Bend the securing tab to 90° and slot the plate over the flue
before bringing the flue through the wall.
3.34 Mark the fixing holes using the wall plate as a template.
The tab can be above or beneath the flue, see Diagram 7.
Flue Aperture
3.35 Mark the height from the top of the hearth to the centre
of the horizontal section, see Diagram 6.
6
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Huntingdon 20-30-40 - Balanced Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Huntingdon 20-30-40 - Balanced Flue in the language / languages: English as an attachment in your email.

The manual is 3.33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info