7. MAIN INJECTOR
7.1 Follow steps 2.1 to 2.5 to remove the burner unit. Making
sure the gas supply is isolated at the isolation point. Turn
the burner unit over to access the main injector pipe. Undo
the compression fittings both ends of the pipe and remove.
See diagram 10
10
AR2015
7.2 Unscrew the injector and remove.
7.3 Reassemble in reverse order, the injector must NOT be
tightened into the burner but allowed to float to enable it to
line up with the pipe. Turn on the gas supply and check for
leaks.
8. GAS VALVE
8.1 Follow the steps 2.1 to 2.5 to remove the burner unit,
making sure the gas supply is isolated at the isolation point.
Undo the compression nuts on the injector pipe and inlet
pipe and remove these pipes. Undo the compression nut
on the pilot pipe, lift the pipe clear of the valve.
11
AR2015
10. GAZCO FLUE SURE SYSTEM
10.1 Open and remove the front door. Remove the glass frame.
Carefully remove the ceramic components and place to one
side. Undo the two screws at the back of the firebox and
carefully withdraw the bracket. See diagram 12
12
AR1442
10.2 Disconnect the two sender wires. Undo the two taptite
screws and remove the sensor and the two plastic spacers.
See diagram 13
13
AR1446
10.3 Refit the new sensor ensuring that the plastic spacers are
between the sensor and the bracket. Refit the leads. See
diagram 14
14
AR1452
10.4 Feed the cable back through the hole as you replace the
bracket. When the bracket is located correctly it will sit
flush with the back panel without force required. If not
positioned correctly the bracket will sit at an angle. See
diagram 15
18
SERVICING INSTRUCTIONS
REPLACING PARTS
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco F40 Avanti Conventional Coal at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco F40 Avanti Conventional Coal in the language / languages: English as an attachment in your email.

The manual is 3.44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info