821027
6
Zoom out
Zoom in
Previous page
1/11
Next page
1110
On position
In the On position the valve is opened after a delay of 2 seconds and then
automatically closed again after 30 minutes. If the water timer is switched
to On during an automatic watering program the valve stays open and is
closed after 30 minutes.
Off position
In the Off position, an open valve is closed after a delay of 2 seconds.
10. Changing the Setting
The time and the watering time can be changed using the control knob
(Run Time).
The changes are accepted after approx. 5 seconds and this is signalled
acoustically by a double beep. If the water timer is not reset the original
starting time remains unchanged.
Making changes during watering
You can change the watering time (Run Time) during an automatic
watering program as follows:
.If the elapsed watering time is shorter than the new watering time
you have selected, then the new watering time is valid.
Example:
Old Run Time = 10 minutes, changed after 5 minutes to 30 minutes.
The total watering time is then 30 minutes.
.If the watering time which has already expired is longer than the new
watering time, the water flow is interrupted in the next minute.
If you have already chosen the starting time (Start Time / Run Time
already set) any changes you make to the watering frequency
(Frequency) are active as soon as the next watering program starts.
If you have forgotten the current start time, you should reset the Water
Timer and then re-enter the watering data.
9.3 Examples
Current time: 9:00 am.
The watering program should run as follows:
Example a) Every day at 9:00 for 10 minutes.
Example b) 3 x a day (= every 8 hours) for 2 minutes. at 10:00,
at 18:00 and at 2:00.
Example c) Every 3 days at 16:00 for 60 minutes.
The timer should be programmed as follows:
Step 1 Step 2 Step 3
Setting Setting Start Time
Frequency Run Time key
Example a) 24 h 10 min. do not press
Example b) 8 h 2 min. press once
Example c) 3rd 60 min. press 7 times
The watering time has now been changed. The water timer will now
automatically run the required watering programs.
9.4 Turning off the watering programs
The watering programs can be switched off for any period of time
e.g. in periods of bad weather as follows:
1. Turn the Run Time knob 3clockwise to Off.
2. To restart the watering e.g. at the end of the bad weather period,
turn the Run Time knob 3back to the required watering time.
Note: The starting time you previously selected remains unchanged
so that your garden is watered at the usual times (the times you pro-
grammed).
9.5 Manual On/Off operation
In addition to watering your garden fully automatically, the Water Timer
can be operated manually by turning the Run Time knob 3to On or Off.
Automatic watering programs during this time are not executed or inter-
rupted. After manually opening / closing the valve (On/Off) you can once
again select a watering time. A watering starting time which you deter-
mined earlier remains unchanged.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gardena 1805 - T1030 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gardena 1805 - T1030 in the language / languages: English as an attachment in your email.

The manual is 0.16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gardena 1805 - T1030

Gardena 1805 - T1030 User Manual - German - 19 pages

Gardena 1805 - T1030 User Manual - Dutch - 19 pages

Gardena 1805 - T1030 User Manual - French - 22 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info