Installation CK 482
The appliance is installed in a base cabinet with a
width of more than 900 mm. As the hob is fixed in
place, it has to be easily accessible from below in
case of repairs.
The surface of the installed hob should not be
below the worktop surface.
Through dimensional tolerance of the glass ceramic
plate and the worktop cut out, the width of the joint
may vary.
• Clean and degrease the edge of the cut-out, using
a suitable cleaner (follow the instructions given by
the silicone manufacturer).
• Insert the hob with the control panel front right
into the cut-out and align it. Make sure to leave an
even space all round.
• Secure the appliance to the worktop with the
clamping screws included. Make sure the
appliance is flush with the worktop.
27
CK 482 is suitable for flush mounting into
stone or tiled worktops.
Other worksurfaces (i.e. wood, plastic,
Corian, etc.) are unsuitable.
min. 60
793
513
490
±2,5
780
±2,5
min. 30
46
min. 50
800
±2,5
520
±2,5
Querschnitt
490
±2,5
520
±2,5
(15)
3,5
±2
mit Silikon
ausfüllen
7
(15)
3,5
±2
Längsschnitt
780
±2,5
800
±2,5
(10)
(10)
7
3,5
±2
3,5
±2
mit Silikon
ausfüllen
Cross section as
seen from the front
fill out with
silicone
Cross section as
seen from the side
fill out with
silicone
800
±1
780
±1
520
±1
490
±1
R 9
R 5
as seen from above
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gaggenau CK 482-100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gaggenau CK 482-100 in the language / languages: English as an attachment in your email.

The manual is 0,91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gaggenau CK 482-100

Gaggenau CK 482-100 User Manual - German - 30 pages

Gaggenau CK 482-100 User Manual - Dutch - 30 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info