Configuring emergency operation (PtMP and PtP connections)
Emergency operation is not configured as a factory default feature. A slide switch is located on the bottom of the
system telephone that can be used for configuring emergency operation.
To configure the emergency operation feature, slide the switch on the left side on the bottom of the phone down. To
de-activate emergency operation, slide the switch back to the top position.
Information:
Attention: Before you move the emergency operation switch unplug the ISDN connector for the system telephone.
Use a non-metallic tool to move the switch.
Configuring emergency operation at a point-to-point (PtP) connection
Ifyou wishto alsouse yoursystem telephone for emergencyoperation ata PtP connection you must also activatethis
feature using the PC configuration for your system telephone. You can use the configuration program to set
emergency operation at a PtP connection.
Making calls during emergency operation at a point-to-multipoint connection
The system telephone begins emergency operation when power supply for the PABX system and the NT is lost.
Emergency operation, followed by a telephone symbol is then shown in the system telephone display.
If the 230 V AC power supply is restored during an ongoing call, all normal, configured functions are available again
only after you hang up the handset. If the 230V~ power supply is restored when the handset is in the cradle, the
emergency operation display is replaced by the normal display when the handset is lifted, or on the next call.
Making calls at emergency power supply mode on a point-to-point connection
Duringemergencypowersupplymodeatapoint-to-pointconnection,youwillseethenormaloperationdisplays.
CS410
This system telephone is designed for connection to an internal S0-port (4 wires) of an pabx system. If you wish to
connect the telephone to an internal Up0-port, be sure to install the internal Up0/S0-module into the telephone or
use the external Up0/S0-converter.
CS410-U
This system telephone is designed for connection to an internal Up0-port (2 wires) of an pabx system. The internal
Up0/S0-module or the external Up0/S0-converter is then no longer required.
elmeg IP-S400
Connect this system telephone to the corresponding LAN port (or network) of the PABX system using a Cat. 5 cable.
The system telephone is equipped with a PC output that can be used to connect other IP terminal devices.
Setting up/ Configuring the system telephone (CS410, CS410-U, CS400xt)
On the system telephone itself you can only carry out a limited configuration of the supported features. A full
configuration is only possible with an elmeg telephone system using the professional WIN tool configurator via the
corresponding system telephone interface.
elmeg IP-S400
Connect this system telephone to the corresponding LAN port (or network) of the PABX system using a Cat. 5 cable.
The system telephone is equipped with a PC output that can be used to connect other IP terminal devices. Power
supplied via plug-in power supply unit, or via Ethernet PoE (Power over Ethernet).
Information:
Youwill find additional information on the configuringof the systemtelephones in thedetailed instructionmanual
on the CD-ROM.
Description and installation
2
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Funkwerk CS410 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Funkwerk CS410 in the language / languages: English as an attachment in your email.

The manual is 0,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info