535711
21
Zoom out
Zoom in
Previous page
1/78
Next page
21
POSITIONING THE PIR DETECTORS
The recommended position for a PIR Movement
Detector is in the corner of a room mounted at a
height between 2 and 2.5 metres. At this height,
the detector will have a maximum range of up to
12 metres with a field of view of 110°.
When deciding upon the mounting position for
the detector the following points should be
considered to ensure trouble free operation:
1. Do not position the Detector facing a
window or where it is exposed to or facing
direct sunlight. PIR Detectors are not
suitable for use in conservatories.
2. Do not position the Detector where it is
exposed to draughts.
3. Do not position the Detector directly
above a heat source, (e.g. fire, radiator,
boiler, etc).
4. Where possible, mount the Detector in the
corner of the room so that the logical path
of an intruder would cut across the fan
detection pattern. PIR Detectors respond
more effectively to movement across the
device than to movement directly towards it.
5. Do not position the Detector in a position
where it is subject to excessive vibration.
6. Ensure that the position selected for the
PIR Detector is within effective range of the
Control Panel.
7. Do not fix the PIR Detector onto or very
close to metalwork (i.e. radiators, water
pipes, etc) as this could affect the radio
range of the device.
Note: When the system is Armed, pets should
not be allowed into an area protected by a PIR
Detector as their movement could be detected
and trigger an alarm.
INSTALLING THE PIR MOVEMENT
DETECTOR
1. Undo and remove the fixing screw from the
bottom edge of the PIR Detector, (keep the
screw safe for later). Carefully pull the
bottom edge of the detector away from the
rear cover and then slide down to release
the top clips.
2. Carefully drill out the required mounting
holes in the rear cover using a 3mm drill
according to whether the unit is being
mounted in a corner or against a flat wall.
Flat wall Corner
Drill
holes
for
corner
mount
Drill
holes
for flat
wall
mount
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Friedland HISK1 GlobalGuard Alarm System at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Friedland HISK1 GlobalGuard Alarm System in the language / languages: English as an attachment in your email.

The manual is 2,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info