1. Trigger each security detector by walking into an area protected by a PIR movement detector or by opening a door or
window protected by a door/window contact detector. The control panel chimes. The display shows the ID code of the
zone which the detector is configured to.
2. Remove the battery covers from the PIR movement detectors and the door/window contact detectors to operate the
tamper switches. The control panel chimes. The display shows “Z0X TAMPER”.
3. Activate each button on the remote control (optional accessory) in turn. The control panel chimes. The display shows a
message according to the below table:
Item
Message
R01 DISARM
R01 PART ARM-1
R01 FULLY ARM
R01 PANIC
Note: If a PIR movement detector is at low-battery condition, the control panel will chime and the displays will show “Z0X
BATTERY”.
6.1.2 RF environment test (RF ENVIRONMENT)
If there is radio frequency interference, the displays will show “ENVIRON . . POOR.
6.1.3 Wirefree siren service on/off (WIREFREE SIREN SERVICE ON/OFF)
The solar siren has a service mode facility which prevents the tamper switch from triggering an alarm when it is removed from
the wall. Before removing the siren from the wall, set the siren to “SERVICE MODE ON”. After replacing the batteries and
installing the siren, set the siren to “SERVICE MODE OFF”.
If you select “WIREFREE SIREN SERVICE OFF”, the siren will emit one long beep followed by two short beeps.
If you select “WIREFREE SIREN SERVICE ON”, the siren will emit two short beeps followed by one long beep.
6.1.4 Alarm test (ALARM TEST)
Select “RELAY TEST” to operate the external hard-wired relay contacts (NO/NC).
Select “WIREFREE SIREN TEST” to operate the external solar siren.
Select ‘HARDWIRE SIREN TEST’ to operate the control panel siren and the external hard-wired siren.
6.1.5 Resetting the control panel
The control panel will not return to the default factory settings, but all settings and learned devices will be erased from memory.
1. Press the button.
2. Enter the 4-digit PIN code (Admin).
3. Press the button.
4. Switch off the power supply to the power adaptor.
5. Remove the control panel from the wall bracket.
6. Disconnect the power adaptor from the control panel.
7. Remove the battery cover.
8. Remove and disconnect the backup battery.
9. Set jumper link P1 to the on position.
10. Connect and install the backup battery.
11. Install the battery cover.
12. Connect the power adaptor to the control panel.
13. Switch on the power supply to the power adaptor. The control panel powers up. The display shows “EEPROM RESET”.
After the process is completed, the display shows “DISARM READY”.
14. Set jumper link P1 to the off position.
15. Install the control panel to the wall bracket.
Note: After resetting the control panel, always first learn the devices into the control panel again.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Friedland GlobalGuard Home Alarm System at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Friedland GlobalGuard Home Alarm System in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 3,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Friedland GlobalGuard Home Alarm System

Friedland GlobalGuard Home Alarm System Installation Guide - English, German, Dutch, French, Italian, Portuguese, Spanish - 120 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info