Maintenance
Replacing the Test Leads
You can replace a worn out or damaged test lead. To
get a replacement test lead, contact your local Fluke
Networks authorized distributor.
Warning
Read all instructions completely and
understand possible hazards to end user if
repairs are not performed properly.
Before you remove the battery door,
disconnect the test leads from the line.
Install only test leads that are supplied by
Fluke Networks for your model of the test
set.
To remove and install the test leads:
Warning
Make sure you install all the screws and
washers that you removed. Make sure that
you tighten the screws. Missing or loose
parts can make the test set dangerous to
use.
When you install new test leads, be careful
not to cause damage to the braided
insulation around the cables.
Note
The screws do not come out of the battery
door.
1
Use a Phillips screwdriver to loosen only the three
screws on the battery door (Figure 2).
2
Remove the battery door and battery from the
test set. (Figure 2)
3
Loosen the two screws that attach the test leads to
the test set (Figure 5), then remove the two screws
and washers.
4
Lift the test lead cable out of the strain-relief
channel, then pull out the cable through the hole
in the housing.
5
Use alcohol and a swab to clean the battery
compartment and the connections for the test
leads.
6
Put the lug of the new test lead through the hole
in the housing, then pull approximately 1 inch
(25 mm) of cable through the hole. Push the cable
down into the strain-relief channel.
7
Install the screw and washer to attach the lug to
the test set. Figure 5 shows the correct installation
for the lugs.
8
Install the battery and the battery door. Tighten
the screws on the battery door to a maximum
torque of 0.904 N-m or 8 in-lb.
GOLO8.eps
Figure 5. How to Remove and Install the Test Leads
Red (ring)
Black (tip)
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke networks TS23 PRO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke networks TS23 PRO in the language / languages: English as an attachment in your email.

The manual is 0,76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info