5
Operation
To use the PowerTone System:
1
Connect the tester to a wire pair; then turn on the
tester.
2
At the other end of the cable, use your tone probe
to find the wire pair by probing for the pair with
the loudest tone.
3
Short the wire pair together, then release the
short.
If you DO NOT hear a change in the tone,
then you have not found the correct pair.
If you DO hear a change, then you have
POSITIVE CONFIRMATION that you have
found the correct pair.
Note
The tone is not audible on the tester’s beeper.
bfz02.eps
Figure 2. PowerTone Positive Identification System
Table 1. LED Display and Beeper Indications
Condition Display
1
Beeper
Normal conditions,
open cable
2
LLLL Off
Normal conditions,
shorted cable
LLLL Continuous On
Cable is too long to
measure
–Err Staggered
A dc load (light bulb,
TV, etc.) is detected
–Err Staggered
>15 Vac is detected 8888
Flashing
Rapid
Low battery, open
cable
L.LLL Off
Failed self test 8888 Off
Cable cannot be
measured
–Err Staggered
1. LLLL = the length to the fault.
2. An open may be a break in a wire or a separation
between the wires in the pair. If one wire in the pair
separates from the other wire for 1 ft (30 cm) or more,
the tester indicates an open at the separation.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke networks TS 100 Cable Fault Finder at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke networks TS 100 Cable Fault Finder in the language / languages: English as an attachment in your email.

The manual is 0,55 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info