Users Manual
4-16
Common Commands
Table 4-8 describes common commands.
Table 4-8. Common Commands
Command Name Description
*CLS Clear Status Clears all event registers summarized in the status
byte (except Message Available, which is cleared
only if *CLS is the first message in the command
line).
*ESE <value> Event Status Enable Sets Event Status Enable Register to <value>, where
<value> is an integer between 0 and 255.
<value> is an integer whose binary equivalent
corresponds to the state (1 or 0) of bits in the register.
If <value> is not between 0 and 255, an Execution
Error is generated.
EXAMPLE: Decimal 16 converts to binary 00010000,
which sets bit 4 (EXE) in ESE to 1.
*ESE? Event Status Enable Query Meter returns the <value> of the Event Status Enable
Register as set by the *ESE command.
<value> is an integer whose binary equivalent
corresponds to the state (1 or 0) of bits in the register.
*ESR? Event Status Register Query Meter returns the <value> of the Event Status
Register and then clears it.
<value> is an integer whose binary equivalent
corresponds to the state (1 or 0) of bits in the register.
*IDN? Identification Query Meter returns the identification code of the Meter as
four fields separated by commas. These fields are:
Manufacturer (FLUKE); model (8808A); seven-digit
serial number; and versions of main software and
display software.
*OPC Operation Complete
Command
Meter sets the Operation Complete bit in the
Standard Event Status Register when parsed.
*OPC? Operation Complete Query Meter places an ASCII 1 in the output queue when
parsed.
*RST Reset Meter performs power-up reset.
76


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 8808A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 8808A in the language / languages: English as an attachment in your email.

The manual is 1,96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke 8808A

Fluke 8808A User Manual - German - 102 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info