Operating the Meter from the Front Panel
Introduction 3
3-5
Table 3-1. Front-Panel Features (cont.)
No. Name Description
I J Primary operation: Sets the Meter’s measurement rate to slow,
medium or fast
Second level operation: Selects source for triggering
measurement
J I Primary operation: Selects Touch Hold function
Second level operation: Sets Touch Hold minimum response
level
K T Primary operation: Selects relative readings function to display
difference between relative base and input
Second level operation: Sets relative base
L W Primary operation: Selects dB measurement mode
Second level operation: sets dB reference impedance
M N Stores the minimum and maximum inputs measured
N
F
D
A
E
B
O
G
Selects measurement function:
Frequency
DC voltage
AC voltage
DC current
AC current
Resistance (ohms)
Continuity / diode test (toggles)
O R Toggles between manual and autorange modes
Uand V increase and decrease the range for manual
ranging
P 10 A Input terminal for 10 A ac and dc current measurement
Q mA Input terminal for 200 mA ac and dc current measurement
39


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 8808A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 8808A in the language / languages: English as an attachment in your email.

The manual is 1,96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke 8808A

Fluke 8808A User Manual - German - 102 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info