Operating the Meter from the Front Panel
Introduction 3
3-3
Introduction
The Meter can be controlled either by sending commands through its RS232
communication interface or through the front panel. This chapter explains the function
and use of the controls and indicators located on the front panel of the Meter. Operating
the Meter through its RS232 communication interface is covered in Chapter 4.
The front panel has three main elements: input terminals (on the left), dual display
(primary and secondary displays), and keypad. See Figure 3-1 for an overview of the
front panel and refer to Table 3-1 for descriptions of the front-panel features.
The front panel is used to:
Select a measurement function (volts dc, volts ac, current dc, current ac,
resistance, frequency, and diode/continuity test) for the primary and/or secondary
displays
Take a measurement and display a reading
Select the manual or autorange mode
Manually select a measurement range for the primary display
Select function modifiers that cause the Meter to display relative readings,
minimum or maximum values, or to select the TouchHold® function to hold a
reading on the primary display
Change the measurement rate (slow, medium, fast)
Take a measurement and compare it against a tolerance range
Use the editor to select from option lists, to enter a relative base, or to enter a
high (HI) or low (LO) range for the compare mode
Configure the computer interface (RS-232)
Send measurements directly to a printer or terminal through the RS-232 interface
37


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 8808A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 8808A in the language / languages: English as an attachment in your email.

The manual is 1,96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke 8808A

Fluke 8808A User Manual - German - 102 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info