763940
41
Zoom out
Zoom in
Previous page
1/100
Next page
Operating the Meter from the Front Panel
3
3-7
Table 3-2. Display Annunciators and Indicators
No. Name Description
A r Meter is in remote mode (remotely controlled)
B L the front panel is locked out
C Ext Trig Meter is in external trigger mode
D S Q is pressed and secondary function will be selected
E RELX Relative readings function modifier is selected
F Measurement value in secondary display is negative
G H Touch Hold function modifier is selected
H M Minimum maximum function modifier is selected
I MAX and MIN Reading is maximum or minimum
J AC DC Form of voltage displayed in secondary display
K 2x4 Wire Resistance measurement method selected (2-wire or 4-
wire)
L mV µmA kHz Mke Unit of measurement displayed in secondary display
M R G Continuity test or diode test is selected
N mV µmA Mke kHz Unit of measurement displayed in primary display
O AC DC Form of voltage displayed in primary display
P Slow, Medium, Fast Measurement rate selected (slow, medium, fast)
Q Measurement value in primary display is negative
R Setup 8 annunciator Which configuration is currently selected
S Print Meter is in RS-232 print-only mode
T * (asterisk) Flashes for each Meter sample cycle
U Auto Range Meter is in auto range mode
V Manual Range Meter is in manual range mode
W CAL Error Calibration attempt failed
X Y High voltage is detected
Displays when voltage is >30 V dc or ac rms
41


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 8808A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 8808A in the language / languages: English as an attachment in your email.

The manual is 1,96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke 8808A

Fluke 8808A User Manual - German - 102 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info