3 Phase Power Quality Analyzer
Energy Analyze Plus Software
23
WiFi Direct Connect
With the built in WiFi/BLE Adapter you can wirelessly control the Analyzer and download
measurement data to the Energy Analyze Plus software. The WiFi direct connection uses
WPA2-PSK (pre-shared key) with AES encryption.
To make a WiFi connection:
1. If not already, enable the WiFi Access Point on the Analyzer.
For more information, see Basic Setup - Communication Settings. Stay in this screen to get
the WiFi passphrase that is required to connect from a device to the Analyzer.
The status bar indicates the enabled WiFi Access Point with <. When one or more
devices are connected, this icon turns orange.
2. On the client, go to the list of available WiFi networks and look for a network with the name:
“Fluke177x<serial-no>” for example: “Fluke1777<12345678>”.
3. At the prompt for WiFi passphrase, enter the passphrase from the WiFi Access Point
configuration screen.
Depending on the operating system of the client, the passphrase is also called Security
Key, Password, or similar. After a few seconds, the connection is established.
A blue WiFi Hotspot LED indicates an established connection with a client.
Note
Windows checks if the WiFi connection enables an Internet connection. This may take
up to one minute until the Analyzer is accessible. A missing Internet connection is
indicated by the “No Internet” (an exclamation mark or a globe) icon in the Windows
task bar if this is the only network connection. This is normal since the Analyzer is not a
gateway to the Internet.
WiFi to Infrastructure
The WiFi/BLE Adapter also supports a simultaneous connection to a WiFi access point. This
connection requires a DHCP service running in the access point to assign IP addresses
automatically.
To connect to an access point:
1. Select the access point from the list of found SSID (Service Set Identifier - name of the
access point).
2. Enter the passphrase (8 to 63 characters) of the access point.
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 1775 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 1775 in the language / languages: English as an attachment in your email.

The manual is 3.36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info