763951
17
Zoom out
Zoom in
Previous page
1/22
Next page
True-rms Multimeter
Making Basic Measurements
13
Measuring Current above 600 μA
The millivolt and voltage function of the Meter can be used with an optional mV/A output
Current Probe to measure currents that exceed the rating of the Meter. Make sure the Meter
has the correct function, AC or DC, selected for your current probe. Refer to a Fluke catalog or
contact your local Fluke representative for compatible current clamps.
Using the Bargraph
The bar graph is like the needle on an analog meter. It has an overload indicator ( ) to the right
and a polarity indicator (+) to the left.
Because the bar graph is much faster than the digital display, the bar graph is useful for making
peak and null adjustments.
The bar graph is disabled when measuring capacitance. In frequency, the bar graph and range
annunciator indicates the underlying voltage or current up to 1 kHz.
The number of segments indicates the measured value and is relative to the full-scale value of
the selected range.
In the 60 V range, for example (see below), the major divisions on the scale represent 0, 15, 30,
45, and 60 V. An input of -30 V turns on the negative sign and the segments up to the middle of
the scale.
CLAMPMETER
i410
ZEROA
600V
CAT
600V
600A
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 116 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 116 in the language / languages: English as an attachment in your email.

The manual is 1,41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke 116

Fluke 116 User Manual - German - 22 pages

Fluke 116 User Manual - Dutch - 22 pages

Fluke 116 Quick start guide - All languages - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info