Specifications
17
Hz (V or A input)[3]
99.99 Hz 0.01 Hz
0.1 % + 2
999.9 Hz 0.1 Hz
9.999 kHz 0.001 kHz
50.00 kHz 0.01 kHz
Notes:
[1] All ac ranges except Auto-V LoZ are specified from 1 % to 100 % of range. Auto-V LoZ is specified from 0.0 V.
Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-
zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of
3 at 4000 counts, decreasing linearly to 1.5 at full scale. For amps, crest factor of 3. AC volts is ac-coupled.
Auto-V LoZ, AC mV, and AC amps are dc-coupled.
[2] AC Volts Hz is ac-coupled and specified from 5 Hz to 99.99 kHz. Minimum input required above 50.00 kHz typically is
>1.1 vac sine. Minimum input typical and not specified. AC Amps Hz is dc-coupled and specified from 45 Hz to 5 kHz.
[3] W>10 A unspecified.Duty cycle: >10 A to 20 A, 30 seconds on, 10 minutes off.
Table 7. Input Characteristics
Function Input Impedance
(Nominal)
Common Mode Rejection Ratio
(1 kΩ Unbalanced) Normal Mode Rejection
Volts AC >5 MΩ <100 pF >60 dB at dc, 50 or 60 Hz - - -
Volts DC >10 MΩ <100 pF >100 dB at dc, 50 or 60 Hz >60 dB at dc, 50 or 60 Hz
Auto-V LoZ ~3 kΩ <500 pF >60 dB at dc, 50 or 60 Hz - - -
Open Circuit Test
Voltage Full Scale Voltage Short Circuit Current
Ohms <2.7 V dc to 6.0 MΩ40 MΩ<350 μA
<0.7 V dc <0.9 V dc
Diode Test <2.7 V dc 2.000 V dc <1.2 mA
Table 6. Accuracy Specifications (cont.)
Function Range Resolution Accuracy
± ([% of Reading] + [Counts])
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 116 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 116 in the language / languages: English as an attachment in your email.

The manual is 1,41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke 116

Fluke 116 User Manual - German - 22 pages

Fluke 116 User Manual - Dutch - 22 pages

Fluke 116 Quick start guide - All languages - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info