456445
6
Zoom out
Zoom in
Previous page
1/11
Next page
Cod. 710.056.02.00 – Rev. 04 – 07.06.2001
ENGLISH
page 17 of 63
3.3 PARAMETERS PROGRAMMING
HOW TO CHANGE THE SET POINT
Press the SET key (the display will show the set point value previously set).
Change the set point value displayed using the UP / DOWN keys (the change must be made within 15
seconds after having pressed the SET key, other ways the controller goes automatically to the normal
operation mode, and the DEW POINT value will be displayed without the possibility to change the SET
POINT).
Confirm the new value by pressing the SET key (this key must be pressed within 10 seconds after the end
of the previous operation, other ways the controller goes automatically to the normal operation mode, and
the DEW POINT value will be displayed without any change to the SET POINT).
The newly entered SET POINT value will blink to confirm that new data have been accepted and stored. 15
seconds later, the controller will return to the normal operation mode.
CONTROL AND CHANGE OF CONFIGURATION PARAMETERS
Hold down the SET key for 10 seconds to access the parameters configuration menu: the display will show
in sequence the set point value, the code of the first E1 modifiable parameter, and its value).
Only if strictly necessary, use the keys UP and/or DOWN to change the value of the displayed parameter.
Press the SET key to store the value of the parameter previously changed, or to browse the parameters
without changing them.
15 seconds after the last performed operation, the controller will go automatically to the normal operation
mode.
NOTE: Changes entered for timing values will be effective only after exiting the programming, while changes to other
variables will be immediately effective.
Please remember that eventual changes to the configuration parameters of the machine could negatively affect its
efficiency. Thus, changes have to be arranged in collaboration with the manufacturer.
3.4 BEFORE START UP
Before to start the machine, make sure that all the operating parameters correspond to the nominal data.
The dryer is supplied already tested and preset for normal operation, and it doesn’t require any calibration.
Nevertheless, during few hours after start up it has to be checked for proper operation.
3.5 START UP
The operations specified below must be performed after the first start up and at each start up after a
prolonged inactive period of time due to maintenance operations, o any other reason.
Make sure that all instructions contained in chapters INSTALLATION SITE and INSTALLATION
have been respected.
Check for proper closure the by-pass system (if present) .
Activate the mains and press the illuminated switch on the control panel of the dryer.
Wait a couple of minutes to let the machine reach the standard operating parameters
Open slowly the air outlet valve and, successively, again slowly, open the air inlet valve.
If present, close the by-pass system.
Check the condensate drain system for proper operation.
Check for proper tightness and stability all the connecting tubing.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Finicompressors Artic 134-12 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Finicompressors Artic 134-12 in the language / languages: English as an attachment in your email.

The manual is 0,19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Finicompressors Artic 134-12

Finicompressors Artic 134-12 User Manual - German - 11 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info