632697
7
Zoom out
Zoom in
Previous page
1/56
Next page
EN
7
Ferm
• Remove the air filter cover (16).
• Remove filter element and wash well in
solvent.
• Pour a small amount of oil onto the filter
element and gently squeeze out any excess
oil.
• Replace the filter element and air filter cover.
• Be sure the filter cover seals properly all
around.
Do not run the engine without the air filter
element in place.
Never place a wet filter (with solvent) on
the machine.
Fuel tap
• To remove the fuel tap filter, simply undo the
cup at the bottom of the fuel tank
• Use a small spanner to remove the tap
• Clean and wash out the filter and cup, and
replace.
Troubleshooting
Basic checks
• Make sure you have plenty of fuel
• Make sure the fuel tap is on
• Make sure the engine-switch is on
• Make sure the oil level is correct
• The generator has an oil sensor. When the oil
level is too low, the generator will not be able to
start.
• Remove spark plug, connect spark plug lead
and earth it to the generator. Pull starter cord
gently and look for a spark. If there is no spark,
replace spark plug.
Spark plug is OK, but engine still won’t start
• Check fuel tap filter is clean
• Check fuel line is clear
• Check carburetor is not clogged
Engine will not start
• Clean or replace spark plug
• Check ignition system – if faulty, contact your
service centre
• Check compression – if low, contact your
service centre
• Check for loose cylinder head – tighten bolts
• Check for damaged cylinder head gasket –
replace if necessary
Cleaning
Clean the housing regularly with a soft cloth,
preferably every time it is used. Keep the air vents
free of dust and dirt.
Remove stubborn dirt with a soft rag moistened in
soapy water. Do not use any solvents such as
petrol, alcohol, ammonia, etc. as such substances
can damage the plastic parts.

• Drain fuel tank, fuel tap, carburetor bowl and
carburetor
• Pour 1 cup of engine oil into the fuel tank and
shake the generator to spread the oil around
the tank. Drain excess oil.
• Remove spark plug and pour in 1 spoonful of
engine oil, pull the starter cord several times
with the starter switch OFF. Replace spark
plug.
• Pull on the starter cord until you feel
compression and stop.
• Clean the generators exterior and coat with
rust inhibitor.
• Place the generator on flat ground and cover
with a clean dry cloth.
Faults
Should a fault occur, e.g. after wear of a part,
please contact the service address on the warranty
card. In the back of this manual you find an
exploded view showing the parts that can be
ordered.
Environment
To prevent damage during transport, the appliance
is delivered in a solid packaging which consists
largely of reusable material. Therefore please
make use of options for recycling the packaging.
Faulty and/or discarded electrical or
electronic apparatus have to be collected
at the appropriate recycling locations.

Do not dispose of power tools into domestic waste.
According to the European Guideline 2012/19/EU
for Waste Electrical and Electronic Equipment
and its implementation into national right, power
tools that are no longer usable must be collected
separately and disposed of in an environmentally
friendly way.

Read the terms of warranty on the separate
warranty card which is enclosed.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ferm PGM1012 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ferm PGM1012 in the language / languages: English, German, Dutch, French, Polish, Swedish, Spanish, Finnish as an attachment in your email.

The manual is 4,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info