632697
6
Zoom out
Zoom in
Previous page
1/56
Next page
EN
6 Ferm
• Clean up any spilled fuel
• Do not smoke while operating the generator
Always use caution!
Starting the generator
Fig. 1 + 4 + 5
1. Turn on fuel tap (15).
2. Turn on engine switch (12).
3. Move choke lever (13) to closed position (to
restart a warm engine, leave the choke lever in
open or half-open position).
4. Pull slowly on the starter cord until it engages,
then pull sharply to start the engine (14).
5. Allow the engine to run until it warms up, and
then move the choke lever to the open position
(13).

• Start the generator.
• Plug in the electrical appliance plug.
• Press AC current protector downward to
“ON”(7).
• The voltmeter (11) displays the voltage on the
AC socket. Normally this should be ± 230 V
during use.
Stopping the generator
Fig. 1 + 5
1. Unplug all cords (5)
2. Turn engine switch to “OFF” (12)
3. Turn off fuel tap (15)
4. Service & Maintenance
Periodic maintenance

• Check engine oil level
• Check fuel hose for cracks or other damage.
Replace if necessary.
• Check exhaust-system for leakage. Retighten
or replace gasket if necessary.
• Check choke operation
• Check recoil starter operation
1st Month or 20 hrs
• Replace engine oil

• Check condition of spark plug. Adjust gap and
clean. Replace if necessary.
• Clean, replace if necessary.
6 Months or 100 hrs
• Replace engine oil
• Clean fuel tap and fuel tank filter. Replace if
necessary.
• Check fittings and fasteners. Replace if
necessary.
12 Months or 300 hrs
• Contact a specialized service centre to check
the valve clearance.
• Check the fan of the cooling system for
damage.
Service – notes on maintenance
Fig.1
Oil replacement
• Warm up engine on level ground
• Remove filler cap (8)
• Open drain plug (9) and let oil drain completely
into a pan placed under the engine.
• Check gaskets, replace if required. Refit drain
plug and refill engine with clean oil.
• Replace filler cap.
Spark plug inspection
Fig. 3
• Disconnect the spark plug cap, and remove
any dirt from around the spark plug area.
• Remove spark plug (17) with the plug spanner
supplied.
• Inspect the spark plug. It should be a tan
colour.
• Measure the gap (distance contact point) with
a suitable gauge. The gap should be 0,7 - 0,8
mm. Correct the gap, if necessary, by carefully
bending the side electrode.
• Replace the spark plug if the electrodes are
worn, or if the insulator is cracked or chipped.
• Install the spark plug carefully, by hand, to
avoid cross-threading.
• Place the spark plug with correct torque: 20
Nm.
• Attach the spark plug cap.
Exhaust screen
• Wait for exhaust to cool.
• Exhaust screen may be blocked up with
carbon deposits.
• Undo the screw cap and remove the exhaust
screen.
• Clean the screen with a wire brush and refit.
• Replace exhaust screen if damaged.

6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ferm PGM1012 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ferm PGM1012 in the language / languages: English, German, Dutch, French, Polish, Swedish, Spanish, Finnish as an attachment in your email.

The manual is 4,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info