workpieces:
• Fix the piece of work in place using the clamp
• Screw up the knob (10) a half turn
anticlockwise.
• Slide the machine completely towards
yourself
• Turn on the machine using the switch
• Bring the saw slowly downwards so the saw
blade saws through the piece of work
• Push the machine slowly backwards (in
direction of guide fence)
• Bring the machine gently up again and switch
it off by letting go of the switch
Using the laser
Fig. 2b
To switch on the laser, press the on/off switch
24.
To switch off the laser, release the on/off
switch 24.

Always make sure that the machine is not
connected to the mains electricity when
you carry out any maintenance of the
mechanism.
Slide rails
Dirt can damage the slide rails and thereupon the
operating of the machine.
• Clean the slide rails regularly with a soft cloth.
• Drip some lubricating oil on the slide rails
• Move the mitre saw forwards and backwards
so the oil spreads over the complete rails
Ferm machines are designed to function for a
long time without any problems with a minimum of
maintenance. By cleaning the machine regularly
and using it in the correct way you can contribute
to a long life of your machine.
Problem solving
 
• The plug is not in the socket
• The power cord is broken
• The switch is defective. Take the machine to
your Ferm dealer for repair.
 
• The saw blade must be sharpened
• The saw blade is mounted back to front
• The saw blade is clogged with resin or
sawdust
• The saw blade is not suitable for the piece of
work being used
 
• Chips and/or dust must be removed
 
speed
• The extension cord is too thin and/or too long
• The mains voltage is less than 230 V
 
• The saw blade is damaged
 
• The ventilation slots are blocked. Clean them
out with a dry cloth.
 
• The carbon brushes are worn out. Replace
the carbon brushes or consult your Ferm
dealer.
Cleaning
Clean the machine housing regularly with a soft
cloth, preferably after each time you use the
machine. Make sure that the ventilation slots are
free of dust and dirt. For stubborn dirt use a soft
cloth dampened with soapy water. Never use
solvents such as benzene, alcohol, ammonia, etc.
These types of solvents can damage the plastic
parts.
Lubrication
The machine does not need any extra lubrication.
Faults
Should a fault occur, e.g. after wear of a part,
please contact the service address on the
warranty card. In the back of this manual you find
an exploded view showing the parts that can be
ordered.
Environment
To prevent damage during transport the machine
is delivered in sturdy packaging. The packaging
is made of recyclable material wherever possible,
so make use of the possibility of recycling the
packaging. When you replace a machine, take the
old one to your local Ferm dealer. Here it will be
dealt with in an environmentally friendly way.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ferm MSM1031 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ferm MSM1031 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 6,19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info