632694
8
Zoom out
Zoom in
Previous page
1/36
Next page
DE
8
Ferm
The compressor will not start
• If the compressor is difficult to start, check:
• whether the voltage of the mains corresponds
to that on the specification plate (fig. 10)
• whether electrical extension cables are being
used with a faulty core or length.
• whether the operating environment is too cold
(below 0°C).
• whether there is electricity supply (plug
properly connected, magneto-thermal fuses
not broken).
The compressor does not shut off
If the compressor does not shut off when the
maximum pressure has been reached, the safety
valve of the tank will be activated. It is necessary
to contact the nearest authorised Support Service
for the repair.
Repairs and servicing should only be
carried out by a qualified technician or
service firm.
Cleaning
Regularly clean the machine housing with a soft
cloth, preferably after each use. Keep the
ventilation slots free from dust and dirt. If the dirt
does not come off use a soft cloth moistened with
soapy water. Never use solvents such as petrol,
alcohol, ammonia water, etc. These solvents may
damage the plastic parts.
Drain the tank
Compressing air will cause water in the tank.
Regularly drain the water from the tank to prevent
tank corrosion (fig 16):
• First reduce the pressure in the tank till
aprroxially 2 bar by connecting and activating
an air tool .
• Then slowly turn the drain valve (10) on the
lower side of the tank open.
• The water in the tank will now leak out of the
tank
Clean the air filter
Clean the air filter of the compressor every 50
operation hours ( fig 15 )
Lubrication
It is recommended to disassemble the suction filter
every 50 operating hours and to clean the filter
element by blowing it with compressed air (fig. 15).
It is recommended that the filter element is
replaced at least once a year if the compressor is
working in a clean environment; more often if the
environment in which the compressor is situated is
dusty. The compressor makes condensed water
which collects in the tank. It is necessary to
remove the condensed water in the tank at least
once a week by opening the drain cock (fig. 16)
under the tank. Take care when compressed air is
in the bottle because the water can come out with
some force. Recommended pressure max. 1-2
Bar.
Faults
Should a fault occur, e.g. after wear of a part,
please contact the service address on the
warranty card. In the back of this manual you find
an exploded view showing the parts that can be
ordered.
Environment
To prevent damage during transport, the appliance
is delivered in a solid packaging which consists
largely of reusable material. Therefore please
make use of options for recycling the packaging.
Faulty and/or discarded electrical or
electronic apparatus have to be collected
at the appropriate recycling locations.
Warranty
The warranty conditions can be found on the
separately enclosed warranty card.
KOMPRESSOR
Die Nummern im nachfolgenden text
korrespondieren mit den Abbildungen auf
Seite 2 - 4.
Lesen Sie diese Bedienungsanleitung
aufmerksam, bevor Sie die Maschine in
Betrieb nehmen. Machen Sie sich mit der
Funktionsweise und der Bedienung
vertraut. Warten Sie die Maschine
entsprechend der Anweisungen, damit
sie immer einwandfrei funktioniert. Die
Betriebsanleitung und die dazugehörige
Dokumentation müssen in der Nähe der
Maschine aufbewahrt werden.
Inhalt
1. Gerätedaten
2. Sicherheitsvorschriften
CRM1041 Ma 1403-18.indd 8 4/24/14 10:16 AM
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ferm CRM1041 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ferm CRM1041 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 9,98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info