sloping and smooth, make sure that the
compressor will not move when in operation. If the
surface area is a board or a shelf of a bookcase,
just make sure that they cannot fall down by
securing them properly. For proper ventilation and
effective cooling, it is important that the
compressor is positioned at least 100 cm from the
wall (fig. 4).
Make sure that the compressor is
transported in the right way, do not turn it
upside down and don’t lift it with hooks or
ropes (fig. 5-6).
Starting up
• Check whether the mains voltage corresponds
to that indicated on the electrical specification
plate (fig. 10), the permitted tolerance range
should be within 5%.
• Press the switch situated on the upper part
into the “0” position according to the pressure
regulator type fitted on the device (fig. 11). Put
the power plug in the plug socket (fig. 9) and
start the compressor by pulling the switch (3)
to the “I” position. The operation of the
compressor is fully automatic. The pressure
regulator will stop the compressor when the
maximum value has been reached and start it
up when the pressure drops below the
minimum value. Normally the difference in
pressure is approx. 2 Bar/29 psi between the
maximum and the minimum value. For
instance - The compressor will stop when it
reaches 8 Bar (116 psi) (this is the maximum
operating pressure) and will start up
automatically when the pressure within the
tank has dropped to 6 Bar (87 psi).
The head/cylinder/transmission pipe
assembly may reach high temperatures,
so take care when working close to these
parts and do not touch them to avoid
burns (fig. 12 - 13).
Adjusting the operating pressure
Fig. 14
It is not necessary continuously to use the
maximum operating pressure, the compressed-air
tools often require less pressure. With regard to
compressors supplied with a pressure reduction
valve it is necessary to set the operating pressure
properly.
It is possible to set the operating pressure by
(fig. 14) using the turning knob on the reduction
valve (5)
• By turning clockwise, the pressure will be
increased.
• By turning anti-clockwise, the pressure will be
reduced.
The set pressure can be locked by turning the ring
under the turning knob in the opposite direction
from the turning knob thereby fixing the turning
knob. The set pressure is visible on the
manometer of the reduction valve.
4. Maintenance
Make sure that the plug is removed from
the mains when carrying out maintenance
work on the motor.
The machines have been designed to operate
over a long period of time with a minimum of
maintenance. Continuous satisfactory operation
depends upon proper machine care and regular
cleaning. Before interfering in any way whatsoever
with the compressor, please make sure that:
• The switch button is in the “0” position and the
power plug is removed from the power socket
• The pressure regulator and the switches on
the switch board are switched off in the “0”
position.
• The air tank is fully decompressed (both
pressure gauges must be pointed at 0 Bar)
Malfunction
Should the machine fail to function correctly, a
number of possible causes and the appropriate
solutions are given below:
Air loss
• Check all air connections by wetting them with
a soapy water solution ( Never use the
solution nearby electric connections )
• When the tank is empty and being filled. The
user might hear a sisseling sound by the
pressure switch. This is normal and will stop
before the compressor reach a pressure of 1.5
bar
• Check if the drain valve ( 10 ) is closed well
The compressor runs but does not compress
Fig. 19
• May be caused by the valves (C-C2) or a
gasket (B1-B2) being broken.
• Replace the damaged part.
CRM1041 Ma 1403-18.indd 7 4/24/14 10:16 AM
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ferm CRM1041 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ferm CRM1041 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 9,98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info