WARNING - SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity supply before servicing. Check appliance is safe when you have finished.
Page 25
Note
Ensure that the floor covering below the range is firmly fixed or
removed to prevent disturbance whilst positioning the appli-
ance.
Figure 2
1.2.2 Levelling
The unit must be levelled following placement. The height at
the back is adjusted by using the hex end of the spanner on
the rear rollers. The front is levelled by initially turning the ad-
justing screw of the near roller clockwise until the desired
height is achieved. Following this, position the levelling feet by
screwing them down. When the unit is level, turn the front
roller adjuster anti-clockwise until the weight is transferred
from the roller to the feet.
1.2.3 APPLIANCE LOCATION
The unit may be installed in a kitchen/kitchen diner but not in a
room that contains a bath or shower.
1.2.4 Position of Appliance
The space required above the hotplate is indicated in Figure
1.
A width of 1115mm is required up to hotplate level to accom-
modate the additional width required when the doors are
opened fully.
A minimum overhead distance of 800mm is required above
the hob.
Curtains must not be fitted immediately behind the appliance.
Any extraction hood should be installed in accordance with
the manufacturer’s instructions.
1.3 ELECTRICAL SUPPLY
1.3.1 ELECTRICAL CONNECTION
This appliance must be installed by a qualified elec-
trician to comply with the relevant Institute of
Electrical Engineers (I.E.E.) regulations and also lo-
cal electricity supply company requirements.
WARNING - THIS APPLIANCE MUST BE EARTHED!
Note: The unit must be connected to the correct electrical sup-
ply as stated on the data label. A suitable control unit which
incorporates a double pole switch with contact separation of at
least 3mm in all poles must be fitted. This type of unit should
NEVER be connected to a regular power socket.
With diversity taken into consideration, we recommend the
use of a 40 - 45 amp cooker point.
Access to mains terminal is gained by removing electrical ter-
minal cover box on back panel. Connect mains cable to
terminals as indicated below.
Fig. 4
The unit is Type X with regard to protection against the over-
heating of surrounding surfaces.
Current Operated Earth Leakage Breakers
In the event of an installation being protected by a 30mA sen-
sitivity residual current device (RCD), the combined use of the
unit and other domestic appliances may occasionally cause
nuisance tripping. In such instances, the cooker circuit may re-
quire to be protected by fitting a 100mA device. Such work
should be carried out by a qualified electrician.
1.4 ELECTRICAL RATINGS
1.4.1 Hob Element Ratings (230V - 50hz)
Hob Element Rating
Front Left 1.1kW
Rear Left 1.4kW
Rear Right 1.1kW
Front Right 1.1kW
Centre 2.7kW
1.4.2 ADDITIONAL ELECTRICAL RATINGS (230V
- 50HZ)
LH Oven - 2.0kW Browning Element 1.05kW
RH Oven - 2.3kW Grill Element 2.1kW
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Falcon 211 EEO Ceramic at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Falcon 211 EEO Ceramic in the language / languages: English as an attachment in your email.

The manual is 0,94 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info