FIGURE 17
Turn the power supply on. Turn on blower and light. If the rangehood does not operate, check that the circuit breaker is not
tripped or the house fuse blown. If the unit still does not operate, disconnect the power supply and check that the wiring connec-
tions have been made properly.
USE AND CARE INFORMATION
This rangehood system is designed to remove smoke, cooking vapors and odors from
the cooktop area.
For Best Results
Start the rangehood several minutes before cooking to develop proper airflow. Allow the
unit to operate for several minutes after cooking is complete to clear all smoke and odors
from the kitchen.
Cleaning
The metal grease filters should be cleaned frequently in hot detergent solution or washed
in the dishwasher. Stainless steel cleaner should be used on stainless rangehoods.
Abrasives and scouring agents can scratch stainless steel finishes and should not be
used to clean finished surfaces.
Replacing the Lamps
Before attempting to replace the lamps, make sure that the light switch is turned off.
Remove the 2 screws (as indicated in FIGURE 17) that hold the light support and gently
pull the support down from the hood. Remove the lamp from the light support and replace
with new lamp. Replace the light support and fix it into place with the 2 screws.
An alternative method to replace the lamps is to use a 1 1/4" suction cup (FIGURE 18).
Attach the suction cup to the bulb and pull firmly down on the bulb and replace with a
new lamp.
1. Remove the cover from the field wiring compartment. Remove
the wiring electrical knockout using a flat-blade screwdriver. Feed
the Power Supply Cable through the electrical knockout.
2. Connect the Power Supply Cable to the rangehood. (FIGURE
14) Attach the White lead of the power supply (A) to the White
lead of the rangehood (D) with a twist-on type wire connector.
Attach the Black lead of the power supply to the Black lead
of the rangehood (B) with a twist-on type wire connector (C).
Connect the Green (E) (Green and Yellow) ground wire under
the Green grounding screw.
3. Replace the field wiring compartment cover and the grease
filters.
1. Connect the vent system and seal all connections with
clamps.
2. Install the upper chimney (see FIGURE 15) Slightly spread the sides
of the cover apart and hook them behind the chimney mounting brackets.
Attach the cover to the brackets with 4 mounting screws.
3. Install the lower chimney (FIGURE 16), slightly spread the sides of
the cover apart and hook them behind the upper chimney and the wall.
Slide the lower
chimney down to fit securely into the top of the range hood.
NOTE: For vented installations, the lower chimney cover can
be installed with the vent slots at the top. For non-vented
(recirculating) installations, the lower chimney cover must be
installed with the vent slots at the bottom.
ELECTRICAL CONNECTION
FIGURE 18
FINISH THE INSTALLATION
FIGURE 14
FIGURE 15
FIGURE 16
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Faber Classica at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Faber Classica in the language / languages: English, French as an attachment in your email.

The manual is 1,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info