ENGLISHENGLISH
END-USER GUIDE
412 Automation Systems
Fig. 1
SBLOCCA
DESBLOQUEAR
DEBLOQUE
UNLOCK
ENTRIEGELT
BLOCCA
BLOQUEAR
BLOQUE
LOCK
VERRIEGELT
SBLOCCA
DESBLOQUEAR
DEBLOQUE
UNLOCK
ENTRIEGELT
BLOCCA
BLOQUEAR
BLOQUE
LOCK
VERRIEGELT
Read the end user guide carefully before using the product
and keep it in a safe place for future reference.
GENERAL SAFETY REGULATIONS
When correctly installed and used, the 412 automation
system ensures a high degree of safety.
A few simple rules should be followed to prevent accidental
problems.
- Do not pass between the leaves when they are still moving:
always wait until they have opened completely.
- Do not linger between the leaves.
- Do not linger near the automation system; do not allow
children or adults to linger near it; and do not leave
objects near it.
- Keep wireless control devices, or other devices that might
accidentally activate the automation system, out of the
reach of children.
- Do not allow children to play with the automation system.
- Do not impede the movement of the leaves.
- Do not allow branches or bushes to interfere with the
movement of the leaves.
- Ensure that the warning lamps are in always in working
order and visible.
- Do not attempt to actuate the leaves manually unless you
have first unlocked them.
- In case of a malfunction, unlock the leaves to allow
vehicles to pass, and call a qualified technician.
- If you have set the manual mode, before restoring normal
operation, disconnect the power supply.
- Do not modify the components of the automation system.
- Do not attempt to repair the automation system or to
perform any operation on it. Call qualified technicians
only.
- At least once every 6 months, have qualified personnel
check that the automation system, safety devices and
earth connection are in working order.
DESCRIPTION
The FAAC 412 automation consists of two
electromechanical operators which are ideal for controlling
swinging gates with each leaf up to 1.80 m long.
The two electromechanical operators transmit movement
to the leaves by a worm screw system.
The operators are controlled by an electronic control unit,
mounted in an enclosure which assures adequate
protection against atmospheric agents.
The leaves are normally closed. When the electronic control
unit receives an open command from the remote radio
control or any other control device, it activates the
electromechanical system and causes the leaves to rotate
by an angle of up to 110° to their open position, so as to
allow access.
If automatic operation has been selected, the leaves close
automatically after the selected pause time.
If semiautomatic operation has been selected, a second
impulse must be sent to close the leaves.
An open command given while the leaves are closing
causes the leaves to reverse direction of movement.
A stop command (if available) stops movement at any
time.
For detailed information on the operation of the automation
system in the various operating modes, contact the
installation technician.
The automation system is equipped with a photocell safety
device which prevents the leaves from closing when the
photocells are darkened by an obstacle.
The 412 automation system is also equipped with an anti-
crushing safety device (fitted as standard) that limits the
torque transmitted to the leaves.
The operators ensure that the system is mechanically locked
when the motor is not running, so there is no need to install
a lock.
The leaves can be opened manually only by operating the
unlocking device.
The lamp flashes while the leaves are moving.
MANUAL OPERATION
If the gate has to be operated manually due to a malfunction
or power supply failure, remove the safety cap and insert
the key provided into the release system as shown in fig. 1.
To release the operator, turn the key in the leaf closure
direction (fig. 1).
Open or close the leaf manually.
RETURNING TO NORMAL OPERATION
To prevent an accidental impulse from activating the
operators during this operation, disconnect the system
from the power supply before re-locking the operators.
To re-lock the operator, turn the key in the leaf opening
direction (fig. 1).
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for FAAC 412 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of FAAC 412 in the language / languages: English as an attachment in your email.

The manual is 0,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info